UNIGATE IC/IC2 PROFINET device comparison

Feature UNIGATE IC-PN-3,3V 2Port UNIGATE IC-PN-3,3V 1Port UNIGATE IC2-PN-3,3V 2Port
Memory for script code (byte) 32.512 32.512 16.256
Memory for script variable (byte) 16.384 16.384 16.384
Max. fieldbus length (byte) 1.440 1.440 1.024
Height with transformer n.a. 11 n.a.
Height without transformer 8 n.a. 8
Voltage supply versions 3.3 V 3.3 V 3.3 V
Server-Side-Includes (SSI)
Script/Config-Update via FTP
Pinout diverent to 2 port
Order no. (variant) V3804 (3.3 V)1 V4437 (3.3 V)1

1 without Transformer (magnetics)