en:WINGATE: Unterschied zwischen den Versionen
Zur Navigation springen
Zur Suche springen
Reith (Diskussion | Beiträge) |
K |
||
Zeile 5: | Zeile 5: | ||
#Install WINGATE and start. | #Install WINGATE and start. | ||
#At the first start will open a '''"dialog window"''' showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with '''"OK"'''. | #At the first start will open a '''"dialog window"''' showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with '''"OK"'''. | ||
− | #Via the menue item '''"Options"''' | + | #Via the menue item '''"Options"'''→'''"Port"''' select the used COM-Port. If there exists no real COM-Port at the PC, an [[USB-to-RS232 converter]] is needed. |
#Then start UNIGATE® in '''Configuration Mode'''. WINGATE will show the startup message of the UNIGATE®. | #Then start UNIGATE® in '''Configuration Mode'''. WINGATE will show the startup message of the UNIGATE®. | ||
− | #Via the menue item '''"File"''' | + | #Via the menue item '''"File"'''→'''"Upload"''' the configuration of UNIGATE® can be read now. |
#Via the menue items '''"more items visible"''' und '''"more items editable"''' more parameters (if available) are shown and maybe changed. | #Via the menue items '''"more items visible"''' und '''"more items editable"''' more parameters (if available) are shown and maybe changed. | ||
− | #Via the menue item '''"File"''' | + | #Via the menue item '''"File"'''→'''"Download"''' the changed configuration now can be loaded into the UNIGATE®. |
− | #Via the menue item '''"File"''' | + | #Via the menue item '''"File"'''→'''"Save as"''' the configuration of UNIGATE® can be saved and filed. |
#Done. | #Done. | ||
Zeile 17: | Zeile 17: | ||
#Install WINGATE and start. | #Install WINGATE and start. | ||
#At the first start will open a '''"dialog window"''' showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with '''"OK"'''. | #At the first start will open a '''"dialog window"''' showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with '''"OK"'''. | ||
− | #Via the menue item '''"Options"''' | + | #Via the menue item '''"Options"'''→'''"Port"''' select the used COM-Port. If there exists no real COM-Port at the PC, an [[USB-to-RS232 converter]] is needed. |
#Then start the UNIGATE® in '''Data Exchange Mode'''. In the status bar will appear the message '''"Device started in WINGATE-Mode"'''. | #Then start the UNIGATE® in '''Data Exchange Mode'''. In the status bar will appear the message '''"Device started in WINGATE-Mode"'''. | ||
− | #Via the menue item '''"Extras"''' | + | #Via the menue item '''"Extras"'''→'''"Upload_Config_Debug"''' the configuration of the UNIGATE® can be read. |
#Via the menue items '''"more items visible"''' und '''"more items editable"''' more parameters (if available) are shown and maybe changed. | #Via the menue items '''"more items visible"''' und '''"more items editable"''' more parameters (if available) are shown and maybe changed. | ||
− | #Via the menue item ''''"Extras"''' | + | #Via the menue item ''''"Extras"'''→'''"Download_Config_Debug"''' the changed configuration now can be loaded into the UNIGATE®. |
− | #Via the menue item '''"File"''' | + | #Via the menue item '''"File"'''→'''"Save as"''' the configuration of the UNIGATE® can be saved and filed. |
#Done. | #Done. | ||
Zeile 29: | Zeile 29: | ||
#Install WINGATE and start. | #Install WINGATE and start. | ||
#At the first start will open a '''"dialog window"''' showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with '''"OK"'''. | #At the first start will open a '''"dialog window"''' showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with '''"OK"'''. | ||
− | #Via the menue item '''"Options"''' | + | #Via the menue item '''"Options"'''→'''"Port"''' select the used COM-Port. If there exists no real COM-Port at the PC, an [[USB-to-RS232 converter]] is needed. |
#Then start the UNIGATE® in '''Configuration-Mode'''. WINGATE will show the startup message of the UNIGATE®. | #Then start the UNIGATE® in '''Configuration-Mode'''. WINGATE will show the startup message of the UNIGATE®. | ||
− | #Via the menue item '''"File"''' | + | #Via the menue item '''"File"'''→'''"Write Script"''' the needed script (*.dcs) can be selected and is loaded thereafter directly into the UNIGATE®. |
#After that the UNIGATE® will start automatically new and displays a new startup message. | #After that the UNIGATE® will start automatically new and displays a new startup message. | ||
#Done. | #Done. | ||
Zeile 39: | Zeile 39: | ||
#Install WINGATE and start. | #Install WINGATE and start. | ||
#At the first start will open a '''"dialog window"''' showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with '''"OK"'''. | #At the first start will open a '''"dialog window"''' showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with '''"OK"'''. | ||
− | #Via the menue item '''"Options"''' | + | #Via the menue item '''"Options"'''→'''"Port"''' select the used COM-Port. If there exists no real COM-Port at the PC, an [[USB-to-RS232 converter]] is needed. |
#Then start the UNIGATE® in '''Configuration-Mode'''. WINGATE will show the startup message of the UNIGATE®. | #Then start the UNIGATE® in '''Configuration-Mode'''. WINGATE will show the startup message of the UNIGATE®. | ||
− | #Via the menue item '''"Options"''' | + | #Via the menue item '''"Options"'''→'''"Reset Device"''' the reset can be carried out now. |
#The then opening dialog window should be confirmed with '''"Ja"''' only if the '''"Reset Device"''' really should be carried out. The loaded script will be deleted. '''Note for UNIGATE® CL: ''' From version '''V2.64''' the '''Universalscript Deutschmann''' will remain on the device, if this was loaded to it before '''"Reset Device"'''is executed. | #The then opening dialog window should be confirmed with '''"Ja"''' only if the '''"Reset Device"''' really should be carried out. The loaded script will be deleted. '''Note for UNIGATE® CL: ''' From version '''V2.64''' the '''Universalscript Deutschmann''' will remain on the device, if this was loaded to it before '''"Reset Device"'''is executed. | ||
#Done. | #Done. |
Version vom 29. Januar 2015, 10:14 Uhr
By using the configuration software WINGATE UNIGATE® can be configured and a compiled script (*.dcs)can be loaded.
Inhaltsverzeichnis
Device configuration via Application Interface (RS232)
- Install WINGATE and start.
- At the first start will open a "dialog window" showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with "OK".
- Via the menue item "Options"→"Port" select the used COM-Port. If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
- Then start UNIGATE® in Configuration Mode. WINGATE will show the startup message of the UNIGATE®.
- Via the menue item "File"→"Upload" the configuration of UNIGATE® can be read now.
- Via the menue items "more items visible" und "more items editable" more parameters (if available) are shown and maybe changed.
- Via the menue item "File"→"Download" the changed configuration now can be loaded into the UNIGATE®.
- Via the menue item "File"→"Save as" the configuration of UNIGATE® can be saved and filed.
- Done.
Device configuration via Debug Interface
- Install WINGATE and start.
- At the first start will open a "dialog window" showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with "OK".
- Via the menue item "Options"→"Port" select the used COM-Port. If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
- Then start the UNIGATE® in Data Exchange Mode. In the status bar will appear the message "Device started in WINGATE-Mode".
- Via the menue item "Extras"→"Upload_Config_Debug" the configuration of the UNIGATE® can be read.
- Via the menue items "more items visible" und "more items editable" more parameters (if available) are shown and maybe changed.
- Via the menue item '"Extras"→"Download_Config_Debug" the changed configuration now can be loaded into the UNIGATE®.
- Via the menue item "File"→"Save as" the configuration of the UNIGATE® can be saved and filed.
- Done.
Script loading via Application Interface (RS 232)
- Install WINGATE and start.
- At the first start will open a "dialog window" showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with "OK".
- Via the menue item "Options"→"Port" select the used COM-Port. If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
- Then start the UNIGATE® in Configuration-Mode. WINGATE will show the startup message of the UNIGATE®.
- Via the menue item "File"→"Write Script" the needed script (*.dcs) can be selected and is loaded thereafter directly into the UNIGATE®.
- After that the UNIGATE® will start automatically new and displays a new startup message.
- Done.
Reset Device
- Install WINGATE and start.
- At the first start will open a "dialog window" showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with "OK".
- Via the menue item "Options"→"Port" select the used COM-Port. If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
- Then start the UNIGATE® in Configuration-Mode. WINGATE will show the startup message of the UNIGATE®.
- Via the menue item "Options"→"Reset Device" the reset can be carried out now.
- The then opening dialog window should be confirmed with "Ja" only if the "Reset Device" really should be carried out. The loaded script will be deleted. Note for UNIGATE® CL: From version V2.64 the Universalscript Deutschmann will remain on the device, if this was loaded to it before "Reset Device"is executed.
- Done.