The [[#Weblinks|'''GSD-file''' (L200.GSD)]] and a [[#Weblinks|'''S7-example project''']] are available for download on our homepage.
Further information regarding LOCON 200-PB can be found in the manual [[#Weblinks|Cam Controls with Fieldbus-Connection]].
=== LOCON 200-MB (Modbus) ===LOCON 200-MB (Modbus) is '''always''' a Modbus-RTU-Slave and is '''only''' available in the '''2-core cable-version'''. LOCON 200-MB features a RS232-Standard-Interface as well as a RS232-(Modbus-RTU) Interface and a RS485-(Modbus-RTU) Interface, which can be changed by adjusting the rotary coding switch ''High'' located at the bottom side of the device.{| class="wikitable"|+Switch position|-! High !! Low !! Meaning|-| C || x || RS232-Modbus (X = ModbusSlave-ID)|-| D || x || RS485-Modbus without bus termination (x = Modbus-Slave-ID)|-| E || x || RS485-Modbus with activated bus termination (x = Modbus-Slave-ID)|-| F || x || RS232-Standard Interface|}'''Note:''' '''Only''' Modbus-Addresses '''1 ... 15''' (decimal) are supported (right rotary coding switch ''Low'' = ID). The Broadcast address '''0''' is '''not''' supported. The Setting via the rotary coding switch is done in ''hexadecimal''.<br />The following Modbus-RTU-commands are supported by the device: {| class="wikitable"|+Modbus-RTU-commands|-! command !! meaning|-| 03 || (0x03) Read Holding Registers |-| 16 || (0x10) Preset Multiple Regs|}The transmission baud rate is '''19200 Baud'''; '''No Parity'''. Further information regarding LOCON 200-MB can be found in chapter ''LOCON 200 with Modbus'' of the [[#Weblinks|Manual for LOCON 200]]. ===LOCON 200-Out I/O8 (extension module)===
LOCON 200-Out I/O8 is an '''extension module''' and contains 8 I/Os. With this extension module the basic device LOCON 200 resp. (-PB)) can be expanded by 8 I/Os step-by-step to a maximum configuration level of 144 I/Os (incl. the 16 I/Os of LOCON 200 resp. (-PB). LOCON 200-Out I/O8 contains an own processor. Therefore, the switching accuracy (cycle time) is independent of the LOCON 200(-PB) Basic module).
=== NT Module for LOCON 200-Out I/O8 ===
The NT module for LOCON 200-Out I/O8 is a power supply that must be used for a configuration level step of more than 8 LOCON 200-Out I/O8 expansion modules.
The NT module must be inserted immediately after the LOCON 200 basic unit. Nothing can be connected to the NT module itself. The voltage supply of the NT module takes place via the 24V/DC of the LOCON 200 basic unit. The voltage supply of the then following LOCON 200-Out I/O8 expansion modules is adopted by the NT module