UNIGATE IC/IC2 PROFINET device comparison
Feature | UNIGATE IC-PN-3,3V 2Port | UNIGATE IC-PN-3,3V 1Port | UNIGATE IC2-PN-3,3V 2Port |
---|---|---|---|
Memory for script code (byte) | 32.512 | 32.512 | 16.256 |
Memory for script variable (byte) | 16.384 | 16.384 | 16.384 |
Max. fieldbus length (byte) | 1.440 | 1.440 | 1.024 |
Height with transformer | n.a. | 11 | n.a. |
Height without transformer | 8 | n.a. | 8 |
Voltage supply versions | 3.3 V | 3.3 V | 3.3 V |
Server-Side-Includes (SSI) | ✓ | ✓ | ✓ |
Script/Config-Update via FTP | ✓ | ✓ | ✓ |
Pinout | 2-port pinout2 | 1-port-pinout3 | 2-port pinout2 |
Order no. (variant) | V38041 | V3625 | V44371 |
1 without Transformer (magnetics)
2 UNIGATE IC-PN-3,3V 2Port and UNIGATE IC2-PN-3,3V 2Port share the same pinout.