Device replacement ROTARNOCK - PROFIBUS (English): Unterschied zwischen den Versionen

Aus Deutschmann Wiki
Zur Navigation springen Zur Suche springen
Zeile 4: Zeile 4:
 
The configuration has to be done with our software [[WINLOC 32 (English)|WINLOC 32]]-Basis-or Comfortversion. Herefore is needed a corresponding [[Programming cable]]. '''Note:''' If this programming cable should be used for a needed read out of the old device then this has to be checked separately. '''Attention:''' For the configuration, the PC is in need of a real COM-Port. If there is no real COM-Port at the PC, then a [[USB-to-RS232 converter]] has to be used.
 
The configuration has to be done with our software [[WINLOC 32 (English)|WINLOC 32]]-Basis-or Comfortversion. Herefore is needed a corresponding [[Programming cable]]. '''Note:''' If this programming cable should be used for a needed read out of the old device then this has to be checked separately. '''Attention:''' For the configuration, the PC is in need of a real COM-Port. If there is no real COM-Port at the PC, then a [[USB-to-RS232 converter]] has to be used.
 
*'''Virtual encoder resolution:''' If the cam values of the existing electronic cam control should be reused in the new data block, the virtual encoder resolution must be changed to the value of the existing electronic cam control.
 
*'''Virtual encoder resolution:''' If the cam values of the existing electronic cam control should be reused in the new data block, the virtual encoder resolution must be changed to the value of the existing electronic cam control.
*'''Type of idle time compensation:''' Damit die Totzeiten der vorhandenen elektronischen Nockensteuerung im neuen Datenbaustein wiederverwendet werden können, muss die Art der Totzeit (Bitweise; Blockweise; ...) auf die von der vorhandenen elektronischen Nockensteuerung verwendeten Art geändert werden.
+
*'''Type of idle time compensation:''' If the idle times of the existing electronic cam control should be reused in the new data block, then the type of idle time  (Bitwise; Blockwise; ...) has to be set accordingly.
*'''PROFIBUS-Slave-ID:''' Die gewünschte PROFIBUS-Slave-ID muss mit der Software WINLOC 32 eingestellt werden, wenn diese nicht über den PROFIBUS-Master zugewiesen werden soll. Im Auslieferungszustand ist die PROFIBUS-Slave-ID auf 126 eingestellt.
+
*'''PROFIBUS-Slave-ID:''' The desired PROFIBUS-Slave-ID has to be set via WINLOC 32 software, if this if this is not to be assigned via the PROFIBUS master. The PROFIBUS-Slave-ID is set to 126 at delivery state.
*'''Operation modes:''' In conjunction with a PROFIBUS-Master this must be set to '''S7-mode''' This S7-mode is already set in the delivery state.  
+
*'''Operation modes:''' In conjunction with a PROFIBUS-Master this must be set to '''S7-mode'''. This S7-mode is already set at delivery state.  
 
*'''Logic function:''' If the logic function is used in the old device then this function has to be unlocked for ROTARNOCK 100-PB. Therefore a chargeable release code is needed. '''Attention:''' This release code is bounded to the serial-no. and can not be used for other cam controls.
 
*'''Logic function:''' If the logic function is used in the old device then this function has to be unlocked for ROTARNOCK 100-PB. Therefore a chargeable release code is needed. '''Attention:''' This release code is bounded to the serial-no. and can not be used for other cam controls.
  

Version vom 18. Dezember 2017, 10:56 Uhr

ROTARNOCK 1-PB und ROTARNOCK 2-PB can be replaced by ROTARNOCK 100-PB . As an 1:1 exchange is not possible, the following points have to be noted:

Device Configuration

The configuration has to be done with our software WINLOC 32-Basis-or Comfortversion. Herefore is needed a corresponding Programming cable. Note: If this programming cable should be used for a needed read out of the old device then this has to be checked separately. Attention: For the configuration, the PC is in need of a real COM-Port. If there is no real COM-Port at the PC, then a USB-to-RS232 converter has to be used.

  • Virtual encoder resolution: If the cam values of the existing electronic cam control should be reused in the new data block, the virtual encoder resolution must be changed to the value of the existing electronic cam control.
  • Type of idle time compensation: If the idle times of the existing electronic cam control should be reused in the new data block, then the type of idle time (Bitwise; Blockwise; ...) has to be set accordingly.
  • PROFIBUS-Slave-ID: The desired PROFIBUS-Slave-ID has to be set via WINLOC 32 software, if this if this is not to be assigned via the PROFIBUS master. The PROFIBUS-Slave-ID is set to 126 at delivery state.
  • Operation modes: In conjunction with a PROFIBUS-Master this must be set to S7-mode. This S7-mode is already set at delivery state.
  • Logic function: If the logic function is used in the old device then this function has to be unlocked for ROTARNOCK 100-PB. Therefore a chargeable release code is needed. Attention: This release code is bounded to the serial-no. and can not be used for other cam controls.

SPS Projekt

  • GSD-Datei: Um das ROTARNOCK 100-PB in das Projekt einbinden zu können, muss die GSD-Datei (R100.GSD) in die Steuerung geladen werden.
  • AWL-Datei: Die im Projekt befindliche AWL-Datei, die im Datenbaustein abgebildet wird, muss durch eine für ROTARNOCK 100-PB passende AWL-Datei ersetzt werden. Dazu muss der Datenbausteingenerator2 verwendet werden.

Weblinks