Device replacement ROTARNOCK 1, 2, 3 and 4 (English): Unterschied zwischen den Versionen

Aus Deutschmann Wiki
Zur Navigation springen Zur Suche springen
 
(Eine dazwischenliegende Version desselben Benutzers wird nicht angezeigt)
Zeile 6: Zeile 6:
 
# There has to be a real COM-Port on the PC for the configuration and programming of the new device with WINLOC32. If there is no real COM-Port on the PC, you need a USB-RS232-converter.
 
# There has to be a real COM-Port on the PC for the configuration and programming of the new device with WINLOC32. If there is no real COM-Port on the PC, you need a USB-RS232-converter.
 
=== Programming - zero offset - program selection ===
 
=== Programming - zero offset - program selection ===
# The programming of the new device can be performed with a TERM 6, a TERM 24 or with the WINLOC32-Basis or comfort-version. With the PROFIBUS version you can also program via the PROFIBUS.
+
# The programming of the new device can be performed with TERM 6, TERM 24 or with the WINLOC32-Basis or comfort-version. With the PROFIBUS version you can also program via PROFIBUS.
# The zero offset can be performed with a TERM 6, a TERM 24 or with the WINLOC32-comfort-version. With the PROFIBUS version you can also program via the PROFIBUS.
+
# The zero offset can be performed with TERM 6, TERM 24 or with the WINLOC32-comfort-version. With the PROFIBUS version you can also program via PROFIBUS.
# The program selection can be done with a TERM 6, a TERM 24 or via the external program selection. With the PROFIBUS version you can also program via the PROFIBUS.
+
# The program selection can be done with TERM 6, TERM 24 or via the external program selection. With the PROFIBUS version you can also program via PROFIBUS.
 
'''For a corresponding offer please let us know the serial number or the article number (Vxxxx) of the old device and, if used, the serial-no. of TERM 6 resp. TERM 24.'''
 
'''For a corresponding offer please let us know the serial number or the article number (Vxxxx) of the old device and, if used, the serial-no. of TERM 6 resp. TERM 24.'''

Aktuelle Version vom 27. August 2019, 13:28 Uhr

Rotarnock 1,2,3 and 4 as well as the corresponding PROFIBUS variants were replaced by ROTARNOCK 100. This is available with or without PROFIBUS. The following information and components are needed to guarantee a quick exchange and programming of the new device:

  1. The serial number or the article number (Vxxxx) of the old device have to be known to ensure that an appropriate new device can be offered.
  2. If a TERM 6 or a TERM 24 is already in use, we also need to know the serial number of this device to check the compatibility with the new device. Note: TERM 5 is not compatible with ROTARNOCK 100!
  3. To read-out the old device and possibly for the configuration and programming of the new device with the WINLOC32-Basis-or comfort-version, a corresponding Programming cable is needed. Note: Whether the programming cable can also be used for a necessary read-out of the old device has to be tested in each case!
  4. A TERM 6 or the WINLOC32-Basis or comfort-version is needed for the configuration of the new device.
  5. There has to be a real COM-Port on the PC for the configuration and programming of the new device with WINLOC32. If there is no real COM-Port on the PC, you need a USB-RS232-converter.

Programming - zero offset - program selection

  1. The programming of the new device can be performed with TERM 6, TERM 24 or with the WINLOC32-Basis or comfort-version. With the PROFIBUS version you can also program via PROFIBUS.
  2. The zero offset can be performed with TERM 6, TERM 24 or with the WINLOC32-comfort-version. With the PROFIBUS version you can also program via PROFIBUS.
  3. The program selection can be done with TERM 6, TERM 24 or via the external program selection. With the PROFIBUS version you can also program via PROFIBUS.

For a corresponding offer please let us know the serial number or the article number (Vxxxx) of the old device and, if used, the serial-no. of TERM 6 resp. TERM 24.