ENS belongs to the first series of electronic cam control built by Deutschmann Automation. These devices are '''no''' longer supported, a repair is '''not''' possible anymore.  
 
ENS belongs to the first series of electronic cam control built by Deutschmann Automation. These devices are '''no''' longer supported, a repair is '''not''' possible anymore.  
 
== Device Replacement ==
 
== Device Replacement ==
ENS can be replaced by a corresponding [[LOCON 17 (English)|LOCON 17]] or by a corresponding [[LOCON 24 (English)|LOCON 24]] or by a corresponding [[LOCON 200 (English)|LOCON 200]] with a corresponding number of [[LOCON 200 (English).It is highly recommended to also replace the used encoder. The choice of the replacement is depending on the number of needed outputs.
+
ENS can be replaced by a corresponding [[LOCON 17 (English)|LOCON 17]] or by a corresponding [[LOCON 24 (English)|LOCON 24]] or by a corresponding [[LOCON 200 (English)|LOCON 200]] with a corresponding number of extension module [[LOCON 100 (English)#Erweiterungsmodul|LOCON 100-Out I/O32]].It is highly recommended to also replace the used encoder. The choice of the replacement is depending on the number of needed outputs.
Folgende Informationen und Komponenten werden benötigt um einen schnellen Austausch und Programmierung des Neugerätes sicherzustellen:
+
In order to ensure a proper and fast replacement and programming of the new device, we need the following information and components:  
#Alle Angaben auf dem Typenschild des Altgerätes müssen bekannt sein, damit ein entsprechendes Neugerät angeboten werden kann. Beim Einsatz einer neuen Nockensteuerung '''ohne''' Bedienfront ([[LOCON 17| LOCON 17-PM]] oder [[LOCON 24| LOCON 24-PM]] oder LOCON 200) wird zur Bedienung ein [[TERM 6]] oder ein [[TERM 24]] oder [[WINLOC 32]]-Basis- oder Komfortversion benötigt.
+
#All the data listed on the type label has to be known in order to be able to offer a corresponding new device. For the use of a new cam control '''without''' control panel ([[LOCON 17 (English)| LOCON 17-PM]] oder [[LOCON 24 (English)| LOCON 24-PM]] or [[LOCON 200 (English)|LOCON 200]], a [[TERM 6 (English)|TERM 6]] or [[TERM 24 (English)|TERM 24]] or [[WINLOC 32 (English)|WINLOC 32]]-Basic-or-Comfort-Version is needed for operation.
#Für eine ggf. erforderliche Konfiguration des Neugerätes wird ein [[TERM 6]] oder die [[WINLOC 32]]-Basis-oder Komfortversion benötigt.
+
#If a new configuration is required, then the unit has to replaced by [[TERM 6 (English)|TERM 6]] or [[WINLOC 32 (English)|WINLOC 32]]-Basic-or-Comfort Version.
#Für die Konfiguration und Programmierung des Neugerätes mit der WINLOC 32-Basis-oder Komfortversion wird ein entsprechendes [[Programmierkabel]] benötigt.
+
#For the configuration and programming of the new device with WINLOC32-Basic-or-comfort Version a corresponding [[Programming cable]] is needed.
#Für die Konfiguration und Programmierung des Neugerätes mit WINLOC 32-Basis-oder Komfortversion muss ein echter COM-Port am PC vorhanden sein. Wenn kein echter COM-Port mehr am PC vorhanden ist, wird ein [[USB-RS232-Konverter]] benötigt.
+
#For the configuration and programming with WINLOC 32-Basic-or-comfort Version, the PC needs a real COM-Port. If there is no real COM-Port at the PC,then a [[USB-to-RS232 converter]] has to be used.
'''Für ein entsprechendes Angebot teilen Sie uns bitte alle Angaben auf dem Typenschild mit.'''
+
'''For a corresponding offer please let us know all the data listed on the type label.'''
 +
== Replacement by LOCON 200 ==
 +
'''Note:''' If "External Programm Selection" as well as "Programm Start", "Programm Enable" and "Run Control" is used, then would be needed at LOCON 200 up to 9 I/Os. If an absolute parallel encoder is configured, then there will be not enough I/O's at the LOCON 200 in order to realise all the before mentioned functions! If these functions are needed, then please replace the absolute parallel encoder by a SSI-Encoder!

Aktuelle Version vom 2. Juni 2020, 06:35 Uhr

ENS

ENS belongs to the first series of electronic cam control built by Deutschmann Automation. These devices are no longer supported, a repair is not possible anymore.

Device Replacement

ENS can be replaced by a corresponding LOCON 17 or by a corresponding LOCON 24 or by a corresponding LOCON 200 with a corresponding number of extension module LOCON 100-Out I/O32.It is highly recommended to also replace the used encoder. The choice of the replacement is depending on the number of needed outputs. In order to ensure a proper and fast replacement and programming of the new device, we need the following information and components:

  1. All the data listed on the type label has to be known in order to be able to offer a corresponding new device. For the use of a new cam control without control panel ( LOCON 17-PM oder LOCON 24-PM or LOCON 200, a TERM 6 or TERM 24 or WINLOC 32-Basic-or-Comfort-Version is needed for operation.
  2. If a new configuration is required, then the unit has to replaced by TERM 6 or WINLOC 32-Basic-or-Comfort Version.
  3. For the configuration and programming of the new device with WINLOC32-Basic-or-comfort Version a corresponding Programming cable is needed.
  4. For the configuration and programming with WINLOC 32-Basic-or-comfort Version, the PC needs a real COM-Port. If there is no real COM-Port at the PC,then a USB-to-RS232 converter has to be used.

For a corresponding offer please let us know all the data listed on the type label.

Replacement by LOCON 200

Note: If "External Programm Selection" as well as "Programm Start", "Programm Enable" and "Run Control" is used, then would be needed at LOCON 200 up to 9 I/Os. If an absolute parallel encoder is configured, then there will be not enough I/O's at the LOCON 200 in order to realise all the before mentioned functions! If these functions are needed, then please replace the absolute parallel encoder by a SSI-Encoder!