In order to ensure a proper and fast replacement and programming of the new device, we need the following information and components: | In order to ensure a proper and fast replacement and programming of the new device, we need the following information and components: | ||
#All the data listed on the type label has to be known in order to be able to offer a corresponding new device. For the use of a new cam control '''without''' control panel ([[LOCON 17| LOCON 17-PM]] oder [[LOCON 24| LOCON 24-PM]] oder LOCON 200) a [[TERM 6 (English)|TERM 6]] or [[TERM 24 (English)|TERM 24]] or [[WINLOC 32 (English)|WINLOC 32]]-Basic-or-Comfort-Version is needed for operation. | #All the data listed on the type label has to be known in order to be able to offer a corresponding new device. For the use of a new cam control '''without''' control panel ([[LOCON 17| LOCON 17-PM]] oder [[LOCON 24| LOCON 24-PM]] oder LOCON 200) a [[TERM 6 (English)|TERM 6]] or [[TERM 24 (English)|TERM 24]] or [[WINLOC 32 (English)|WINLOC 32]]-Basic-or-Comfort-Version is needed for operation. | ||
− | # | + | #If a new configuration is required, then the unit has to replaced by [[TERM 6 (English)|TERM 6]] or [[WINLOC 32 (English)|WINLOC 32]]-Basic-or-Comfort Version. |
#Für die Konfiguration und Programmierung des Neugerätes mit der WINLOC 32-Basis-oder Komfortversion wird ein entsprechendes [[Programmierkabel]] benötigt. | #Für die Konfiguration und Programmierung des Neugerätes mit der WINLOC 32-Basis-oder Komfortversion wird ein entsprechendes [[Programmierkabel]] benötigt. | ||
#Für die Konfiguration und Programmierung des Neugerätes mit WINLOC 32-Basis-oder Komfortversion muss ein echter COM-Port am PC vorhanden sein. Wenn kein echter COM-Port mehr am PC vorhanden ist, wird ein [[USB-RS232-Konverter]] benötigt. | #Für die Konfiguration und Programmierung des Neugerätes mit WINLOC 32-Basis-oder Komfortversion muss ein echter COM-Port am PC vorhanden sein. Wenn kein echter COM-Port mehr am PC vorhanden ist, wird ein [[USB-RS232-Konverter]] benötigt. | ||
'''Für ein entsprechendes Angebot teilen Sie uns bitte alle Angaben auf dem Typenschild mit.''' | '''Für ein entsprechendes Angebot teilen Sie uns bitte alle Angaben auf dem Typenschild mit.''' |
Version vom 12. April 2017, 10:41 Uhr
ENS belongs to the first series of electronic cam control built by Deutschmann Automation. These devices are no longer supported, a repair is not possible anymore.
Device Replacement
ENS can be replaced by a corresponding LOCON 17 or by a corresponding LOCON 24 or by a corresponding LOCON 200 with a corresponding number of extension module LOCON 100-Out I/O32.It is highly recommended to also replace the used encoder. The choice of the replacement is depending on the number of needed outputs. In order to ensure a proper and fast replacement and programming of the new device, we need the following information and components:
- All the data listed on the type label has to be known in order to be able to offer a corresponding new device. For the use of a new cam control without control panel ( LOCON 17-PM oder LOCON 24-PM oder LOCON 200) a TERM 6 or TERM 24 or WINLOC 32-Basic-or-Comfort-Version is needed for operation.
- If a new configuration is required, then the unit has to replaced by TERM 6 or WINLOC 32-Basic-or-Comfort Version.
- Für die Konfiguration und Programmierung des Neugerätes mit der WINLOC 32-Basis-oder Komfortversion wird ein entsprechendes Programmierkabel benötigt.
- Für die Konfiguration und Programmierung des Neugerätes mit WINLOC 32-Basis-oder Komfortversion muss ein echter COM-Port am PC vorhanden sein. Wenn kein echter COM-Port mehr am PC vorhanden ist, wird ein USB-RS232-Konverter benötigt.
Für ein entsprechendes Angebot teilen Sie uns bitte alle Angaben auf dem Typenschild mit.