In order to load a firmware into your UNIGATE device please use the software Firmware Download Tool. You can find it in our web site's support area.

Depending on the device used the update needs to be carried out via the RS-232 or the Ethernet interface.

Interface
Device RS-232 Ethernet
PROFIBUS
PROFINET
DeviceNet
EtherNet/IP
CANopen
EtherCAT
Ethernet TCP/IP
ModbusRTU
ModbusTCP
RS (232/485/422)
BACnet/IP

Update via RS-232

Please follow the steps below to download the firmware:

  1. Connect the UNIGATE's application interface (RS-232) with your PC.
  2. Start the Firmware Download Tool and select the serial interface (Options->Settings) connected to the UNIGATE.
    • UNIGATE CL: On the device please set the rotary switches S4 and S5 to "F" (Config mode).
    • UNIGATE IC/FC: On the developer board please set the mode switch to "Config".
  3. Now start the device. A start-up message will appear in the Firmware Download Tool.
  4. Select 'Firmware Download' and confirm the warning.
  5. Select the firmware file (file type HEX), select 'Open', then 'OK'.
  6. Select a Baud rate.
  7. Transmission of the firmware should start now.

In the case of a connection loss during the update process please use the button 'Resume Download' instead of 'Firmware Download' for further attempts.

Update via Ethernet

Please follow the steps below to download the firmware:

  1. Connect your UNIGATE with your PC using either a switch or a hub.
  2. Run the Firmware Download Tool, press ‘Firmware Download’ and ‘OK’.
  3. Select the firmware file (type BIN-File) press 'open' and 'OK'.
  4. Enter the IP-Address of the device.
    • UNIGATE CL: On the device please set the rotary switches S4 and S5 to „F“ (Config mode).
    • UNIGATE IC/FC: On the developer board please set the mode switch to „Config“.
  5. Press 'Start Download' and restart the device within 20 seconds.
  6. Transmission of the firmware should start now.