Änderungen

Zur Navigation springen Zur Suche springen
[[Datei:LOCON 100.jpg|thumb|LOCON 100 und Erweiterungsmodul and extension module LOCON 100-Out I/O32]]
== Configuration ==
By factory setting '''all''' LOCON 100 cam controls are configured as follows:
*outputsOutputs: '''16'''
*Encoder type: '''SSI Singleturn'''
*real Real encoder resolution: '''4096'''*virtual Virtual encoder resolution: '''4096'''*idle Idle time: '''Bitwise'''This configuration set by default may configuration can be changed by using [[TERM 6 (English)|TERM 6]] or the software [[WINLOC 32 (English)|WINLOC 32]]. 
== Programming ==
LOCON 100 can be programmed by TERM 6 or [[TERM 24 (English)|TERM 24]] or the software WINLOC 32. The PROFIBUS-Version can be programmed also by via PROFIBUS. The Modbus-version can by programmed by via Modbus. 
== device versions ==
=== LOCON 100 ===
LOCON 100 features a serial RS232-interface and a RS485-([[DICNET (English)|DICNET]]) interface, the needed setting is made through the corresponding rotary coding switches ''High'' und ''Low'' , located at the bottom side of the device.
{| class="wikitable"
|+Switch position
| F || F || RS232-Operation
|}
'''Only''' the DICNET-Addresses '''0 ... 15''' (decimal) are supported (right Rotary rotary coding switch ''Low'' = DICNET-Address). Examples:
{| class="wikitable"
|+Switch Position
|}
'''Note:''' The setting via the rotary coding switches is done in ''hexadecimal''.
 
=== LOCON 100-PB (PROFIBUS) ===
LOCON 100-PB (PROFIBUS) is '''always''' PROFIBUS-Slave and features a serial RS232-interface and a PROFIBUS-Interface, instead of the RS485-(DICNET) Interface, the needed setting is made through the corresponding rotary coding switches ''High'' und ''Low'' , located at the bottom side of the device.
{| class="wikitable"
'''Note:''' The setting via the rotary coding switches is done in ''hexadecimal''.<br />
In LOCON 100-PB two modes are selectable through WINLOC32 via the PROFIBUS-Interface.
* '''S7-Modus''' (Auslieferungszustandex-works condition): Zum Betrieb For an einer operation at a Simatic S7 und zur Verwendung des and for use of the [[DatenbausteinsimulatorData component simulator]]s.* '''KommunikationsprofilmodusCommunication Profile Mode''': Zum Betrieb über das For the Operation via the [[#Weblinks|Kommunikationsprofil für Communication Profile for Deutschmann Nockensteuerungencam controls]].Die The PROFIBUS-Adresse Address (Slave-ID) ist im Auslieferungszustand auf is set by factory Setting on 126 (dezimaldecimal) eingestellt. In den Schalterstellungen If the rotary coding switch is on position "'''00'''" und "'''7E'''" kann über WINLOC 32 oder den then any desired address can be assigned either through WINLOC32 or the PROFIBUS-Master eine beliebige Adresse vergeben werden.Die The [[#Weblinks|'''GSD-Dateifile''' (L100.GSD)]] und ein and 2 example projects [[#Weblinks|'''S7-Beispielprojektexample project''']] stehen zum Download zur Verfügungand [[#Weblinks|'''TIA-example project''']] are available for download on our homepage.Weitere Informationen zum Further information regarding LOCON 100-PB sind dem Handbuch can be found in the manual [[#Weblinks|Nockensteuerungen mit FeldbusanbindungCam Controls with Fieldbus-Connection]] zu entnehmen
=== LOCON 100-MB (Modbus) ===
Das LOCON 100-MB (Modbus) ist is '''immeralways''' ein a Modbus-RTU-Slave und ist and is '''nuronly''' available in der the '''2-Drahtcore cable-Varianteversion''' erhältlich. Das LOCON 100-MB verfügt über eine features a RS232 -Standard Schnittstelle sowie über eine -Interface as well as a RS232-(Modbus-RTU) Schnittstelle und eine Interface and a RS485-(Modbus-RTU) SchnittstelleInterface, die entsprechend über den Drehkodierschalter which can be changed by adjusting the rotary coding switch ''High'' auf der Geräterückseite eingestellt werden könnenlocated at the bottom side of the device.
{| class="wikitable"
|+SchalterstellungSwitch position
|-
! High !! Low !! BedeutungMeaning
|-
| C || x || RS232-Modbus (X = ModbusSlave-ID)
|-
| D || x || RS485-Modbus ohne Busabschluss without bus termination (x = Modbus-Slave-ID)
|-
| E || x || RS485-Modbus mit aktiviertem Busabschluss with activated bus termination (x = Modbus-Slave-ID)
|-
| F || x || RS232-Standard SchnittstelleInterface
|}
'''HinweisNote:''' Es werden '''nurOnly''' die Modbus-Adressen Addresses '''1 ... 15''' (Dezimaldecimal) unterstützt are supported (rechter Drehkodierschalter right rotary coding switch ''Low'' = ID). Die Broadcastadresse The Broadcast address '''0''' wird is '''nichtnot''' unterstütztsupported. Die Einstellung über den Drehkodierschalter erfolgt The Setting via the rotary coding switch is done in ''hexadezimalhexadecimal''.<br />Folgende The following Modbus-RTU-Kommandos werden von dem Gerät unterstütztcommands are supported by the device:
{| class="wikitable"
|+Modbus-RTU-Kommandoscommands
|-
! Kommando command !! Bedeutungmeaning
|-
| 03 || (0x03) Read Holding Registers
| 16 || (0x10) Preset Multiple Regs
|}
Die Übertragungsbaudrate beträgt The transmission baud rate is '''19200 Baud'''; '''No Parity'''. Weitere Informationen zum The manual [[#Weblinks|LOCON 100-MB Communication with ModScan32]] describes how cams are set via a Modbus master. Further information regarding LOCON 100-MB sind dem Kapitel can be found in chapter 8 ''LOCON 100 mit with Modbus'' aus dem of the [[#Weblinks|Handbuch für das Manual for LOCON 100]] zu entnehmen.  === LOCON 100-Out I/O32 (ErweiterungsmodulExtension module) ===Das LOCON 100-Out I/O32 ist ein is an '''Erweiterungsmodulextension module''' und verfügt über and contains 32 I/Os. Damit kann das With this extension module the basic device LOCON 100 bzwresp. (-PB)) auf is expanded to a total of 48 I/Os (inklincl. der 16 I/Os des of LOCON 100 bzw. (-PB)) erweitert werden. Das LOCON 100-Out I/O32 enthält does '''keinennot''' eigenen Prozessorcontain its own processor. Dadurch ist die Schaltgenauigkeit Therefore, the switching accuracy (Zykluszeitcycle time) abhängig vom depends on the LOCON 100 bzw. (-PB)). 
== Weblinks ==
*[httphttps://www.deutschmann.de/produktedownloads/downloadMarketing/Anleitung-Instructions/Handbuecher-Manuals/Nockenschaltwerke%20-%20Cam%20Controls/LOCON%20100/English/LOCON_100-e.php?file_id=285 Handbuch für das pdf Manual for LOCON 100] (PDF-Dateifile)*[httphttps://www.deutschmann.de/produktedownloads/Support/Profibus/downloadL100.php?file_id=270 GSD GSD-Datei für das file for LOCON 100-PB]*[httphttps://www.deutschmann.de/produktedownloads/Support/S7/Nockenschaltwerk_CamSwitch/downloadNsw_v2_e.php?file_id=323 zip S7-Beispielexample project PROFIBUS] (ZIP-file)*[https://www.deutschmann.de/downloads//Support/S7/Nockenschaltwerk_CamSwitch/NSW_PB_TIA_1500.zip TIA-Projektexample project PROFIBUS] (ZIP-Dateifile)*Handbuch Manual [httphttps://www.deutschmann.de/produktedownloads/Marketing/Anleitung-Instructions/Handbuecher-Manuals/downloadDIVERS/Kommunikationsprofil/Kommunikationsprofil%20englisch/komm_profil_e.php?file_id=313 Kommunikationsprofil für pdf Communication profile for Deutschmann Nockensteuerungencam controls] (PDF-Dateifile)*Handbuch Manual [httphttps://www.deutschmann.de/produktedownloads/Marketing/Anleitung-Instructions/Handbuecher-Manuals/Nockenschaltwerke%20-%20Cam%20Controls/NSW%20mit%20Feldbus-CamControlWithFieldbusConnection/English/downloadCamControlsWithFieldbusConnection.php?file_id=319 Nockensteuerungen mit Feldbusanbindungpdf Cam controls with fieldbus connection] (PDF-file)*Manual [https://www.deutschmann.de/downloads/Marketing/Anleitung-Instructions/Handbuecher-Manuals/Nockenschaltwerke%20-%20Cam%20Controls/LOCON%20100/German/LOCON100_MB.pdf LOCON 100-MB Communication with ModSca32] (PDF-Dateifile)
2.226

Bearbeitungen

Navigationsmenü