== Configuration ==
By factory setting '''all''' LOCON 100 cam controls are configured as follows:
*Virtual encoder resolution: '''4096'''
*Idle time: '''Bitwise'''
This configuration set by default may configuration can be changed by using [[TERM 6 (English)|TERM 6]] or the software [[WINLOC 32 (English)|WINLOC 32]]. 
== Programming ==
LOCON 100 can be programmed by TERM 6 or [[TERM 24 (English)|TERM 24]] or the software WINLOC 32. The PROFIBUS-Version can be programmed also by via PROFIBUS. The Modbus-version can by programmed by via Modbus. 
== device versions ==
=== LOCON 100 ===
LOCON 100 features a serial RS232-interface and a RS485-([[DICNET (English)|DICNET]]) interface, the needed setting is made through the corresponding rotary coding switches ''High'' und ''Low'' , located at the bottom side of the device.
{| class="wikitable"
|+Switch position
|}
'''Note:''' The setting via the rotary coding switches is done in ''hexadecimal''.
 
=== LOCON 100-PB (PROFIBUS) ===
LOCON 100-PB (PROFIBUS) is '''always''' PROFIBUS-Slave and features a serial RS232-interface and a PROFIBUS-Interface, instead of the RS485-(DICNET) Interface, the needed setting is made through the corresponding rotary coding switches ''High'' und ''Low'' , located at the bottom side of the device.
{| class="wikitable"
The PROFIBUS-Address (Slave-ID) is set by factory Setting on 126 (decimal).
If the rotary coding switch is on position "'''00'''" und "'''7E'''" then any desired address can be assigned either through WINLOC32 or the PROFIBUS-Master.
The [[#Weblinks|'''GSD-file''' (L100.GSD)]] and a 2 example projects [[#Weblinks|'''S7-example project''']] and [[#Weblinks|'''TIA-example project''']] are available for download on our homepage.
Further information regarding LOCON 100-PB can be found in the manual [[#Weblinks|Cam Controls with Fieldbus-Connection]].
 
=== LOCON 100-MB (Modbus) ===
LOCON 100-MB (Modbus) is '''always''' a Modbus-RTU-Slave and is '''only''' available in the '''2-core cable-version'''. LOCON 100-MB features a RS232-Standard-Interface as well as a RS232-(Modbus-RTU) Interface and a RS485-(Modbus-RTU) Interface, which can be changed by adjusting the rotary coding switch ''High'' located at the bottom side of the device.
| F || x || RS232-Standard Interface
|}
'''Note:''' '''Only''' Modbus-Addresses '''1 ... 15''' (decimal) are supported (right rotary coding switch ''Low'' = ID). The Broadcastaddress Broadcast address '''0''' is '''not''' supported. The Setting via the rotary coding switch is done in ''hexadecimal''.<br />Following The following Modbus-RTU-commands are supported by the device:
{| class="wikitable"
|+Modbus-RTU-commands
| 16 || (0x10) Preset Multiple Regs
|}
The transmission baud rate is '''19200 Baud'''; '''No Parity'''. The manual [[#Weblinks|LOCON 100-MB Communication with ModScan32]] describes how cams are set via a Modbus master. Further Information information regarding LOCON 100-MB can be found in chapter 8 ''LOCON 100 with Modbus'' of the [[#Weblinks|Manual for LOCON 100]].  === LOCON 100-Out I/O32 (Extension module) ===LOCON 100-Out I/O32 is an '''extension module''' and contains 32 I/Os. With this extension module the basic device LOCON 100 resp. (-PB)) is expanded to a total of 48 I/Os (incl. 16 I/Os of LOCON 100 bzw. (-PB)). LOCON 100-Out I/O32 does '''not''' contain an its own processor. Therefore, the switching accuracy (cycle time) depends on the LOCON 100 bzw. (-PB)). 
== Weblinks ==
*[httphttps://www.deutschmann.de/produktedownloads/downloadMarketing/Anleitung-Instructions/Handbuecher-Manuals/Nockenschaltwerke%20-%20Cam%20Controls/LOCON%20100/English/LOCON_100-e.php?file_id=286 pdf Manual for LOCON 100] (PDF-file)*[httphttps://www.deutschmann.de/produktedownloads/downloadSupport/Profibus/L100.php?file_id=270 GSD GSD-file for LOCON 100-PB]*[httphttps://www.deutschmann.de/produktedownloads/Support/S7/Nockenschaltwerk_CamSwitch/Nsw_v2_e.zip S7-example project PROFIBUS] (ZIP-file)*[https://downloadwww.php?file_id=324 deutschmann.de/downloads//Support/S7/Nockenschaltwerk_CamSwitch/NSW_PB_TIA_1500.zip TIA-example projectPROFIBUS] (ZIP-file)*Manual [httphttps://www.deutschmann.de/produktedownloads/Marketing/Anleitung-Instructions/Handbuecher-Manuals/DIVERS/Kommunikationsprofil/downloadKommunikationsprofil%20englisch/komm_profil_e.php?file_id=314 pdf Communication profile for Deutschmann cam controls] (PDF-file)*Manual [httphttps://www.deutschmann.de/produktedownloads/downloadMarketing/Anleitung-Instructions/Handbuecher-Manuals/Nockenschaltwerke%20-%20Cam%20Controls/NSW%20mit%20Feldbus-CamControlWithFieldbusConnection/English/CamControlsWithFieldbusConnection.php?file_id=320 pdf Cam controls with fieldbus connection] (PDF-file)*Manual [https://www.deutschmann.de/downloads/Marketing/Anleitung-Instructions/Handbuecher-Manuals/Nockenschaltwerke%20-%20Cam%20Controls/LOCON%20100/German/LOCON100_MB.pdf LOCON 100-MB Communication with ModSca32] (PDF-file)
2.226