Konfiguration
By factory setting all LOCON 200 cam controls are configured as follows:
- Outputs: 16
- Encoder Type: SSI Singleturn
- Real Encoder resolution: 4096
- Virtual Encoder resolution: 4096
- Idle time: Bitwise
This configuration set by default may be changed by using TERM 6 or the software WINLOC 32.
Programming
LOCON 200 can be programmed by TERM 6 or TERM 24 or the software WINLOC 32. The PROFIBUS-Version can be programmed also by PROFIBUS.
Device versions
LOCON 200
LOCON 200 features a serial RS232-interface and a RS485-(DICNET) interface, the needed setting is made through the corresponding rotary coding switches High und Low , located at the bottom side of the device.
High | Low | Meaning |
---|---|---|
D | DICNET-Adress | DICNET-Operation, Bus Termination inactive |
E | DICNET-Adress | DICNET-Operation, Bus Termination active |
F | F | RS232-Operation |
Only the DICNET-Addresses 0 ... 15 (decimal) are supported (right rotary coding switch Low = DICNET-Address). Examples:
High | Low | Meaning |
---|---|---|
D | 3 | bus termination inactive, DICNET-Address 3 |
E | C | bus termination active, DICNET-Address 12 |
'Note: The setting via the rotary coding switches is done in hexadecimal.
LOCON 200-PB (PROFIBUS)
LOCON 200-PB (PROFIBUS) is always PROFIBUS-Slave and features a serial RS232-interface and a PROFIBUS-Interface, instead of the RS485-(DICNET) Interface, the needed setting is made through the corresponding rotary coding switches High und Low , located at the bottom side of the device.
High | Low | Meaning |
---|---|---|
0 | 0 | PROFIBUS-operation, external address assignment |
0 | 1 | PROFIBUS-operation, Adress 1 |
… | ||
7 | D | PROFIBUS-operation, Adress 125 |
7 | E | PROFIBUS-operation, external address assignment |
F | F | RS232-operation |
Note: The setting via the rotary coding switches is done in hexadecimal.
In LOCON 200-PB two modes are selectable through WINLOC32 via the PROFIBUS-Interface.
- S7-Modus (ex-works condition): For an operation at a Simatic S7 and for use of the Data Block Simulator.
- Communication Profile Mode: For the Operation via the Communication Profile for Deutschmann cam controls.
The PROFIBUS-Address (Slave-ID) is set by factory setting on 126 (decimal). If the rotary coding switch is on position "00" und "7E" then any desired address can be assigned either through WINLOC32 or the PROFIBUS-Master. Die GSD-Datei (L200.GSD) und ein S7-Beispielprojekt stehen zum Download zur Verfügung. Weitere Informationen zum LOCON 200-PB sind dem Handbuch Nockensteuerungen mit Feldbusanbindung zu entnehmen.
LOCON 200-Out I/O8 (Erweiterungsmodul)
Das LOCON 200-Out I/O8 ist ein Erweiterungsmodul und verfügt über 8 I/Os. Damit kann das LOCON 200 bzw. (-PB)) schrittweise bis zu einer maximalen Ausbaustufe von 144 I/Os (inkl. der 16 I/Os des LOCON 200 bzw. (-PB)) erweitert werden. Das LOCON 200-Out I/O8 enthält einen eigenen Prozessor. Dadurch ist die Schaltgenauigkeit (Zykluszeit) unabhängig vom LOCON 200 bzw. (-PB)).
Weblinks
- Handbuch für das LOCON 200 (PDF-Datei)
- GSD-Datei für das LOCON 200-PB
- S7-Beispiel-Projekt (ZIP-Datei)
- Handbuch Kommunikationsprofil für Deutschmann Nockensteuerungen (PDF-Datei)
- Handbuch Nockensteuerungen mit Feldbusanbindung (PDF-Datei)