LOCON 200 and extension module LOCON 200-Out I/O8

Configuration

By factory setting all LOCON 200 cam controls are configured as follows:

  • Outputs: 16
  • Encoder Type: SSI Singleturn
  • Real Encoder resolution: 4096
  • Virtual Encoder resolution: 4096
  • Idle time: Bitwise

This configuration set by default may be changed by using TERM 6 or the software WINLOC 32.

Programming

LOCON 200 can be programmed by TERM 6 or TERM 24 or the software WINLOC 32. The PROFIBUS-Version can be programmed also by PROFIBUS.

Device versions

LOCON 200

LOCON 200 features a serial RS232-interface and a RS485-(DICNET) interface, the needed setting is made through the corresponding rotary coding switches High und Low, located at the bottom side of the device.

Switch Position
High Low Meaning
D DICNET-Adress DICNET-Operation, Bus Termination inactive
E DICNET-Adress DICNET-Operation, Bus Termination active
F F RS232-Operation

Only the DICNET-Addresses 0 ... 15 (decimal) are supported (right rotary coding switch Low = DICNET-Address). Examples:

Switch Position
High Low Meaning
D 3 bus termination inactive, DICNET-Address 3
E C bus termination active, DICNET-Address 12

'Note: The setting via the rotary coding switches is done in hexadecimal.

LOCON 200-PB (PROFIBUS)

LOCON 200-PB (PROFIBUS) is always PROFIBUS-Slave and features a serial RS232-interface and a PROFIBUS-Interface, instead of the RS485-(DICNET) Interface, the needed setting is made through the corresponding rotary coding switches High und Low, located at the bottom side of the device.

Switch Position
High Low Meaning
0 0 PROFIBUS-operation, external address assignment
0 1 PROFIBUS-operation, Adress 1
7 D PROFIBUS-operation, Adress 125
7 E PROFIBUS-operation, external address assignment
F F RS232-operation

Note: The setting via the rotary coding switches is done in hexadecimal.
In LOCON 200-PB two modes are selectable through WINLOC32 via the PROFIBUS-Interface.

The PROFIBUS-Address (Slave-ID) is set on 126 (decimal) in the factory setting. If the rotary coding switch is on position "00" und "7E" then any desired address can be assigned either through WINLOC32 or the PROFIBUS-Master. The GSD-file (L200.GSD) and a S7-example project are available for download on our homepage. Further information regarding LOCON 200-PB can be found in the manual Cam Controls with Fieldbus-Connection. LOCON 200-Out I/O8 (extension module)== LOCON 200-Out I/O8 is an extension module and contains 8 I/Os. With this extension module the basic device LOCON 200 resp. (-PB)) can be expanded by 8 I/Os step-by-step to a maximum configuration level of 144 I/Os (incl. the 16 I/Os of LOCON 200 resp. (-PB). LOCON 200-Out I/O8 contains an own processor. Therefore, the switching accuracy (cycle time) is independent of the LOCON 200(-PB) Basic module).

NT Module for LOCON 200-Out I/O8

The NT module for LOCON 200-Out I/O8 is a power supply that must be used for a configuration level step of more than 8 LOCON 200-Out I/O8 expansion modules. The NT module must be inserted immediately after the LOCON 200 basic unit. Nothing can be connected to the NT module itself. The voltage supply of the NT module takes place via the 24V/DC of the LOCON 200 basic unit. The voltage supply of the then following LOCON 200-Out I/O8 expansion modules is adopted by the NT module