Programming cable: Unterschied zwischen den Versionen

Aus Deutschmann Wiki
Zur Navigation springen Zur Suche springen
 
Zeile 51: Zeile 51:
  
 
=== Programming cabels for ROTARNOCK 1, 2 and 3 ===
 
=== Programming cabels for ROTARNOCK 1, 2 and 3 ===
 +
Whether the programming cable of a ROTARNOCK 100 can be used when a device is exchanged for a '' 'ROTARNOCK 1, 2 or 3' '' must be checked using the item designation. The following points must be observed:
 +
*'''232''' = ROTARNOCK has an RS232 interface only
 +
*'''485''' = ROTARNOCK has an RS485-(DICNET) interface only
 +
*'''PB''' = ROTARNOCK has a PROFIBUS interface and an RS232 interface
 +
*'''PN''' = ROTARNOCK has a PROFINET interface and an RS232 interface
 +
*'''IF''' = ROTARNOCK with protection class IP65 with 28 pin round connector
 +
*'''IP''' = ROTARNOCK with protection class IP65 with interated bus system and 16 pin round connector
 +
'''Example:'''TN65-1000-1-L'''485'''-E-N <br />
 +
This is a ROTARNOCK 1 with an RS485-(DICNET) interface with protection class IP54 and 25 pin D-Sub connector. The right programming cable is '''V3480'''.

Aktuelle Version vom 1. Dezember 2020, 14:41 Uhr

Programming cables for electronic cam controls

If you want to configure or programm a cam control by using the software WINLOC 32-Basic-or-Comfort-Version, you need a corresponding programming cable. Please find here a list of the now available programming cables with the corresponding cam controls.

  • General Note: For the configuration and programming of the cam control by WINLOC 32-Basic-or-comfort Version, the PC needs a real COM-Port. If there isn't a real COM-Port at the PC,then a USB-to-RS232 converter has to be used.
Electronic Cam Control and corresponding programming cable
Art.-No. Device Description cable description length Art.-No.
V3231 ROTARNOCK 4 TN65-4096-4-IPB-E-N Programming cable for ROTARNOCK - 232/PB 2m V3467
V3427 ROTARNOCK 80 TN65-0360-80-I232-E-N Programming cable for ROTARNOCK - 232/PB 2m V3467
V3428 ROTARNOCK 80-PB (PROFIBUS) TN65-0360-80-IPB-E-N Programming cable for ROTARNOCK - 232/PB 2m V3467
V3429 ROTARNOCK 80 TN65-0360-80-I232-E-IFN Programming cable for ROTARNOCK IFN - 232 2m V3712
V3430 ROTARNOCK 80-PB (PROFIBUS) TN65-0360-80-IPB-E-IPN Programming cable for ROTARNOCK - PB/PN IP65 2m V3655
V3413 ROTARNOCK 100 TN65-4096-100-I485-E-N Programming cable for ROTARNOCK (Dicnet) 2m V3480
V3431 ROTARNOCK 100 TN65-4096-100-I232-E-N Programming cable for ROTARNOCK - 232/PB 2m V3467
V3432 ROTARNOCK 100 TN65-4096-100-I485-E-IFN Programming cable for ROTARNOCK (Dicnet) IP65 2m V3483
V3433 ROTARNOCK 100 TN65-4096-100-I232-E-IFN Programming cable for ROTARNOCK IFN - 232 2m V3712
V3628 ROTARNOCK 100 TN65-4096-100-I232-E-N-X089 Programming cable for ROTARNOCK - X89 via TERM 6 2m V2293-02
V3628 ROTARNOCK 100 TN65-4096-100-I232-E-N-X089 Programming cable for ROTARNOCK - X89 via WINLOC 32 3m V2142-03
V3406 ROTARNOCK 100-PB (PROFIBUS) TN65-4096-100-IPB-E-N Programming cable for ROTARNOCK - 232/PB 2m V3467
V3434 ROTARNOCK 100-PB (PROFIBUS) TN65-4096-100-IPB-E-IPN Programming cable for ROTARNOCK - PB/PN IP65 2m V3655
V3795 ROTARNOCK 100-PN (PROFINET) TN65-4096-100-IPN-E-IPN Programming cable for ROTARNOCK - PB/PN IP65 2m V3655
V3542 LOCON 90 LOCON 90 Programming cable for LOCON 90/100/200 2m V3964
V3374 LOCON 100 LOCON 100 Programming cable for LOCON 90/100/200 2m V3964
V3485 LOCON 200 LOCON 200 Programming cable for LOCON 90/100/200 2m V3964
V3397 LOCON 100-PB (PROFIBUS) LOCON 100-PB Programming cable for LOCON 90/100/200 2m V3964
V3487 LOCON 200-PB (PROFIBUS) LOCON 200-PB Programming cable for LOCON 90/100/200 2m V3964
V3589 LOCON 100-MB (Modbus) LOCON 100-MB Programming cable for LOCON 90/100/200 2m V3964
V4310 LOCON 200-MB (Modbus) LOCON 200-MB Programming cable for LOCON 90/100/200 2m V3964

Programming cabels for ROTARNOCK 1, 2 and 3

Whether the programming cable of a ROTARNOCK 100 can be used when a device is exchanged for a 'ROTARNOCK 1, 2 or 3' must be checked using the item designation. The following points must be observed:

  • 232 = ROTARNOCK has an RS232 interface only
  • 485 = ROTARNOCK has an RS485-(DICNET) interface only
  • PB = ROTARNOCK has a PROFIBUS interface and an RS232 interface
  • PN = ROTARNOCK has a PROFINET interface and an RS232 interface
  • IF = ROTARNOCK with protection class IP65 with 28 pin round connector
  • IP = ROTARNOCK with protection class IP65 with interated bus system and 16 pin round connector

Example:TN65-1000-1-L485-E-N
This is a ROTARNOCK 1 with an RS485-(DICNET) interface with protection class IP54 and 25 pin D-Sub connector. The right programming cable is V3480.