* '''Communication Profile Modus''': For Operation via [[#Weblinks|Communication profile for Deutschmann Cam Controls]].<br />
The PROFIBUS-Address (Slave-ID) is set by default to '''126''' (decimal). The [[#Weblinks|'''GSD-file''' (R100.GSD)]] and a [[#Weblinks|'''S7-example project''']] are available for download on our homepage. Further Information regarding ROTARNOCK 100-PB may be found in the manuals [[#Weblinks|"Cam Controls with Fieldbus-Connection"]] und [[#Weblinks|"ROTARNOCK 100 with fieldbus-connection"]].
*'''As replacement for ROTARNOCK 4-PB''': ROTARNOCK 100-PB has the Ident No.: '''3606h'''. If ROTARNOCK 100-PB should be used as replacement for '''ROTARNOCK 4-PB''', the Ident-No. can be changed in WINLOC 32 with the key combination '''"Strg + N"''' into the Ident No.: '''3231h'''. So there have to be done no changes in an existing project. '''NoteAttention:''' If the [[logic function ]] is used for in the ROTARNOCK 4-PB, then this logic function has to the 16 inputs (if used), which are in bytes 9 and 10 in the 5th word are in the PROFIBUS, must be activated for ROTARNOCK 100-PB. Therefore is needed a chargeable release code. 'swapped''Attention:'''This release code is tied the serial-no. and can not be used for any other cam control. <br />*'''As replacement for ROTARNOCK 1-PB; 2-PB and 80-PB''': If ROTARNOCK 100-PB should be used as a replacement for '''ROTARNOCK 1-PB'''; '''ROTARNOCK 2-PB''' or as a replacement for '''ROTARNOCK 280-PB''' , the existing project has to be changed. All neccessary information maybe found under: [[Device replacement ROTARNOCK 1-PB and ROTARNOCK 2-PB (English)|Device replacement ROTARNOCK - PROFIBUS]].
=== ROTARNOCK 100-PN (PROFINET) ===
| PROFINET || RS232 || IP65 || 12 + (32 software outputs)|| V3795
|}
'''Note:''' The 32 software outputs have a delay in the millisecond range. The same also applies to the process data, such as encoder position and speed, which are transferred to the PROFINET. Real-time evaluation of these parameters is not possible; in contrast to the available 12 hardware outputs that switch in real time.<br>
 
The [[#Weblinks|'''GSDML-file''' (GSDML-V2.3-Deutschmann-ROTARNOCK 100-PN-20150317-160500.xml)]] and 2 example projects [[#Weblinks|'''S7-example project''']] and [[#Weblinks|'''TIA-example project''']] are available for download on our homepage.
== Weblinks ==
*[https://www.deutschmann.de/downloads/Marketing/Anleitung-Instructions/Handbuecher-Manuals/Nockenschaltwerke%20-%20Cam%20Controls/ROTARNOCK%20100/English/ROTARNOCK_100_e.pdf Manual for ROTARNOCK 100] (PDF-file)
*[https://www.deutschmann.de/downloads//Support/Profibus/ROTARNOCK%20100%20PROFIBUS/R100.GSD GSD-file for ROTARNOCK 100-PB]
*[https://www.deutschmann.de/downloads/Support/Profinet/GSDML-ROTARNOCK100.zip GSDML-file for ROTARNOCK 100-PN]
*[https://www.deutschmann.de/downloads/Support/S7/Nockenschaltwerk_CamSwitch/Nsw_v2_e.zip S7-example project PROFIBUS] (ZIP-file)