ScriptProgramTool (English): Unterschied zwischen den Versionen
Zur Navigation springen
Zur Suche springen
Reith (Diskussion | Beiträge) |
Reith (Diskussion | Beiträge) |
||
Zeile 1: | Zeile 1: | ||
[[Datei:SPT.JPG|thumb|ScriptProgramTool]] | [[Datei:SPT.JPG|thumb|ScriptProgramTool]] | ||
− | By using ScriptProgramTool (SPT) the compiled script (*.dcs) can be loaded via application | + | By using ScriptProgramTool (SPT) the compiled script (*.dcs) can be loaded into UNIGATE® via application interface (RS232) or via debug-interface. |
− | == Script loading via application | + | == Script loading via application Interface (RS232) == |
− | |||
#Install SPT and then start. | #Install SPT and then start. | ||
− | # | + | # Via the menue item '''"Settings"''' select the used COM-Port. If there exists no real COM-Port at the PC, an [[USB-to-RS232 converter]] is needed. |
#The required script (*.dcs) can by choosen via the menue item '''"File"'''. | #The required script (*.dcs) can by choosen via the menue item '''"File"'''. | ||
#Please confirm the button '''"Download Script"'''. | #Please confirm the button '''"Download Script"'''. | ||
− | #Now will appear a dialog window, | + | #Now will appear a dialog window, UNIGATE® must be restarted in '''"Configuration Mode"'''. |
− | # | + | #In the status bar of SPT will appear the message '''"ApplicationPort connected"'''. |
#Now please confirm the dialog window with '''"OK"'''. | #Now please confirm the dialog window with '''"OK"'''. | ||
#After that, the script download is starting. | #After that, the script download is starting. | ||
#Done. | #Done. | ||
− | #''Note'': If the same script should be loaded on several devices, then the | + | #''Note'': If the same script should be loaded on several devices in a row, then from the second device on, after Step 9, you can continue directly with Step 4. |
== Script loading via debug-interface == | == Script loading via debug-interface == | ||
− | + | From version '''V1.52''' script loading is also supported via debug-interface. | |
− | |||
#Install SPT and then start. | #Install SPT and then start. | ||
− | # | + | # Via the menue item '''"Settings"''' select the used COM-Port. If there exists no real COM-Port at the PC, an [[USB-to-RS232 converter]] is needed. |
#The required script (*.dcs) can by choosen via the menue item '''"File"'''. | #The required script (*.dcs) can by choosen via the menue item '''"File"'''. | ||
#Please confirm the button '''"Download Script"'''. | #Please confirm the button '''"Download Script"'''. | ||
− | #Now will appear a dialog window, | + | #Now will appear a dialog window, UNIGATE® must be restarted in '''"Data Exchange Mode"'''. |
− | # | + | #In the status bar of SPT will appear the message '''"DebugPort connected"'''. |
#Now please confirm the dialog window with '''"OK"'''. | #Now please confirm the dialog window with '''"OK"'''. | ||
#After that, the script download is starting. | #After that, the script download is starting. | ||
#Done. | #Done. | ||
− | #''Note'': | + | #''Note'': If the same script should be loaded on several devices in a row, then from the second device on, after Step 9, you can continue directly with Step 4. |
== Weblinks == | == Weblinks == | ||
[http://www.deutschmann.de/produkte/download.php?file_id=489 Script-Programming-Tool] (Zip-Datei) | [http://www.deutschmann.de/produkte/download.php?file_id=489 Script-Programming-Tool] (Zip-Datei) |
Version vom 28. Januar 2015, 11:35 Uhr
By using ScriptProgramTool (SPT) the compiled script (*.dcs) can be loaded into UNIGATE® via application interface (RS232) or via debug-interface.
Script loading via application Interface (RS232)
- Install SPT and then start.
- Via the menue item "Settings" select the used COM-Port. If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
- The required script (*.dcs) can by choosen via the menue item "File".
- Please confirm the button "Download Script".
- Now will appear a dialog window, UNIGATE® must be restarted in "Configuration Mode".
- In the status bar of SPT will appear the message "ApplicationPort connected".
- Now please confirm the dialog window with "OK".
- After that, the script download is starting.
- Done.
- Note: If the same script should be loaded on several devices in a row, then from the second device on, after Step 9, you can continue directly with Step 4.
Script loading via debug-interface
From version V1.52 script loading is also supported via debug-interface.
- Install SPT and then start.
- Via the menue item "Settings" select the used COM-Port. If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
- The required script (*.dcs) can by choosen via the menue item "File".
- Please confirm the button "Download Script".
- Now will appear a dialog window, UNIGATE® must be restarted in "Data Exchange Mode".
- In the status bar of SPT will appear the message "DebugPort connected".
- Now please confirm the dialog window with "OK".
- After that, the script download is starting.
- Done.
- Note: If the same script should be loaded on several devices in a row, then from the second device on, after Step 9, you can continue directly with Step 4.
Weblinks
Script-Programming-Tool (Zip-Datei)