WINGATE
The software WINGATE® is a configuration software for Deutschmann UNIGATE®-devices. A detailed description of the functions listed below can be found in Manual for WINGATE®.
Inhaltsverzeichnis
Device Configuration
The device configuration maybe done via Application Interface (RS232) or via Debug-Interface.
Application Interface (RS232)
- Install WINGATE and start.
- At the first start will open a "dialog window" showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with "OK".
- Via the menue item "Options"→"Port" select the used COM-Port. If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
- After that the UNIGATE® has to be connected via Application Interface (RS232) and to be started in Configuration Mode (Rotary switches S4 + S5 set to "FF"). WINGATE will show the startup message of the UNIGATE®.
- Via the menue item "File"→"Upload (read from device)" the configuration of UNIGATE® can be read now.
- Via the menue items "more items visible" und "more items editable" more parameters (if available) are shown and maybe changed.
- Via the menue item "File"→"Download (write to device)" the changed configuration now can be loaded into the UNIGATE®.
- Via the menue item "File"→"Save as" the configuration of UNIGATE® can be saved and filed.
- Done.
Debug Interface
- Install WINGATE and start.
- At the first start will open a "dialog window" showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with "OK".
- Via the menue item "Options"→"Port" select the used COM-Port. If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
- After that the UNIGATE® has to be connected via Debug Interface and to be started in Data Exchange Mode (Rotary switches S4 + S5 set to "00").In the status bar will appear the message "Device started in WINGATE-Mode".
- Via the menue item "Extras"→"Upload (read from device) via debug port" the configuration of the UNIGATE® can be read. A "dialog window" will show up with the note: "Restart UNIGATE in Run-Mode and confirm". Before to be able to confirm this "dialog window" with "OK", UNIGATE® has to be started again. Only when in the status bar the message will appear "Device starting in WINGATE-Mode" , this "Dialog Window" maybe confirmed with "OK". Now the upload will be processed. During this process the message "Upload" will be shown in the status bar. After a successfull upload will appear the message "Upload finished" in the Status bar.
- Via the menue items "more items visible" und "more items editable" more parameters (if available) are shown and maybe changed.
- Via the menue item '"Extras"→"Download (write to device) via debug port" the changed configuration now can be loaded into the UNIGATE®. A "dialog window" will show up with the note: "Restart UNIGATE in Run-Mode and confirm". Before to be able to confirm this "dialog window" with "OK", UNIGATE® has to be started again. Only when in the status bar the message will appear "Device starting in WINGATE-Mode" , this "Dialog Window" maybe confirmed with "OK". Now the download will be processed. During this process the message "Downloading..." will be shown in the status bar. After a successfull upload will appear the message "Download finished" in the status bar.
- Via the menue item "File"→"Save as" the configuration of the UNIGATE® can be saved and filed.
- Done.
Script loading
- Install WINGATE and start.
- At the first start will open a "dialog window" showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with "OK".
- Via the menue item "Options"→"Port" select the used COM-Port. If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
- After that the UNIGATE® has to be connected via Application Interface (RS232) and to be started in Configuration Mode. WINGATE will show the startup message of the UNIGATE®.
- Then start the UNIGATE® in Configuration-Mode. WINGATE will show the startup message of the UNIGATE®.
- Via the menue item "File"→"Write Script" the needed script (*.dcs) can be selected and is loaded thereafter directly into the UNIGATE®.
- This process may take some time.
- When the process is finished, a confirmation dialog is shown.
Loading Firmware Script Extension
- Install WINGATE® and start.
- At the first start will open a "dialog window" showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with "OK".
- Via the menue item "Options"→"Port" select the used COM-Port. If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
- After that the UNIGATE® has to be connected via Application Interface (RS232) and to be started in Configuration Mode (Rotary switches S4 + S5 set to "FF"). WINGATE will show the startup message of the UNIGATE®.
- Via the menue item "Extras"→"Firmware script extension" can be selected the corresponding Firmware Script Extension. The window Extension Dlg will show up where the selected Firmware Script Extension is checked.
- If the message "File read without errors" appears the Firmware script extension can be loaded into the UNIGATE® via the button write extension.
- After that a further window has to be closed by the button OK and afterwards the window Extension Dlg has to be closed via the button close.
Generate a sample device description file
A sample device description files can be created with WINGATE®. The compulsory requirement is that the „Universalscript Deutschmann“ is loaded in the UNIGATE®. Note: 'The sample device description file created with WINGATE® can also be used for UNIGATE® devices, in which a customer-specific script is subsequently loaded. Requirement here is that only the fieldbus input data length and the fieldbus output data length are configured. In addition the „Product-Code“ in the device description file has to be compared with the article no. (Vxxx) of the UNIGATE® used. These must be identical.
- Install WINGATE® and start.
- At the first start will open a "dialog window" showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with "OK".
- Via the menue item "Options"→"Port" select the used COM-Port. If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
- After that the UNIGATE® has to be connected via Application Interface (RS232) and to be started in Configuration Mode (Rotary switches S4 + S5 set to "FF"). WINGATE will show the startup message of the UNIGATE®.
- Via the menue item "Extras"→"Upload (read from device)" the configuration of the UNIGATE® can be read.
- Via the menue items "more items visible" und "more items editable" more parameters (if available) are shown and maybe changed.
- The data lengths of the fieldbus input and the fieldbus output must then be determined. The length must be entered via the parameters "Blocklength fieldbus input"' and "Blocklength fieldbus output".
- Via the menue item "Options"→"Generate a sample device description file" can be created a sample device description file.
- Via the menue item "File"→"Download (write to device)" can now be loaded the changed configuration in the UNIGATE®. Note: The created sample device description file has to match with the device configuration of the UNIGATE®.
Reset Device
- Install WINGATE and start.
- At the first start will open a "dialog window" showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with "OK".
- Via the menue item "Options"→"Port" select the used COM-Port. If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
- After that the UNIGATE® has to be connected via Application Interface (RS232) and to be started in Configuration Mode (Rotary switches S4 + S5 set to "FF"). WINGATE will show the startup message of the UNIGATE®.
- Then start the UNIGATE® in Configuration-Mode. WINGATE will show the startup message of the UNIGATE®.
- Via the menue item "Options"→"Reset Device" the reset can be carried out now.
- The then opening dialog window should be confirmed with "Ja" only if the "Reset Device" really should be carried out. The loaded script will be deleted. Note for UNIGATE® CL: From version V2.64 the Universalscript Deutschmann will remain on the device, if this was loaded to it before "Reset Device"is executed.
- This process may take some time.
- When the process is finished, a confirmation dialog is shown.
Weblinks
- Software WINGATE (EXE file)
- Manual for WINGATE (PDF file)