The same way the Ident Number can also be changed back from 3231H to 3606H.
==== How to replace a ROTARNOCK 1/2/3/4 by a ROTARNOCK 100? ====
There are two ways to carry out the exchange.
Important: Please write down the indicated position during downtime (best in the basic position if possible) before removing the old device!
Connect the ROTARNOCK 100 now and carry out an upload or open an existing configuration file. Both, the ROTARNOCK 100 as well as the available configuration file should be unused, otherwise a configuration is not possible. How to set the ROTARNOCK 100 back in default mode can be found here.
Change the current view by clicking on the lettering Configuration. Carry out the configuration now by clicking on Device Reconfiguration on the window's right side.
In WINLOC32 the cam values, idle times and output names are transmitted from the old configuration file to the new one through Extras → Data transfer. This function is only available in the Comfort version of WINLOC 32.
We are pleased to help you transmitting the data also without the Comfort version. To do so, please send an e-mail with both configuration files to [mailto:hotlinesupport@deutschmann.de hotlinesupport@deutschmann.de].
After the data has been transmitted and verified, the complete file can be saved now and loaded into the device. With it the exchange is completed.