en:Protocol Developer: Unterschied zwischen den Versionen
Zur Navigation springen
Zur Suche springen
Reith (Diskussion | Beiträge) |
Reith (Diskussion | Beiträge) |
||
Zeile 3: | Zeile 3: | ||
With Protocol Developer there is the possibilty to debug the programmed resp. created script. Therefore UNIGATE® has to be started in '''Data Exchange Mode''' and has to be connected via '''Debug-Interface''' or '''Application Interface (RS232)''' with the PC resp. Protocol Developer. Further detailed information is to be found under the link [[UNIGATE® interfaces]]. | With Protocol Developer there is the possibilty to debug the programmed resp. created script. Therefore UNIGATE® has to be started in '''Data Exchange Mode''' and has to be connected via '''Debug-Interface''' or '''Application Interface (RS232)''' with the PC resp. Protocol Developer. Further detailed information is to be found under the link [[UNIGATE® interfaces]]. | ||
+ | |||
+ | |||
+ | == Vorhandenes Script an ein anderes Feldbus- oder Industrial-Ethernet-System anpassen == | ||
+ | Mögliche Vorgehensweise: | ||
+ | #Das vorhandene Script muss mit der entsprechenden Script-Vorlage ('''Template''') aus dem Protocol Developer hinsichtlich der busspezifischen Parameter verglichen werden. Diese sind in den Script-Vorlagen ('''Template''') mit „'''!!!'''“ gekennzeichnet. | ||
+ | #*Über den Menüpunkt „'''File'''“ -> „'''New'''“ -> „'''Source'''“ -> „'''Template'''“ kann die entsprechende Script-Vorlage aufgerufen werden. | ||
+ | #Wenn die busspezifischen Parameter identisch sind, muss das Script nicht angepasst werden. Dies gilt allerdings nur dann, wenn bei der Initialisierung des Buses (''':InitFieldbus;''') nicht noch weitere busspezifische, optionale Parameter eingefügt worden sind. Wenn dies der Fall ist, müssen diese optionale Parameter mit der entsprechenden Script-Vorlage ('''Example''') aus dem Protocol Developer verglichen werden. | ||
+ | #*Über den Menüpunkt „'''File'''“ -> „'''New'''“ -> „'''Source'''“ -> „'''Example'''“ -> „'''Include'''“ kann die entsprechende Script-Vorlage aufgerufen werden. | ||
== Weblinks == | == Weblinks == | ||
*[http://www.deutschmann.de/produkte/download.php?file_id=576 Protocol Developer] (Zip-Datei) | *[http://www.deutschmann.de/produkte/download.php?file_id=576 Protocol Developer] (Zip-Datei) |
Version vom 28. Juni 2016, 14:06 Uhr
Protocol Developer is a programming software for Deutschmann UNIGATE®-devices.
Debug-Function
With Protocol Developer there is the possibilty to debug the programmed resp. created script. Therefore UNIGATE® has to be started in Data Exchange Mode and has to be connected via Debug-Interface or Application Interface (RS232) with the PC resp. Protocol Developer. Further detailed information is to be found under the link UNIGATE® interfaces.
Vorhandenes Script an ein anderes Feldbus- oder Industrial-Ethernet-System anpassen
Mögliche Vorgehensweise:
- Das vorhandene Script muss mit der entsprechenden Script-Vorlage (Template) aus dem Protocol Developer hinsichtlich der busspezifischen Parameter verglichen werden. Diese sind in den Script-Vorlagen (Template) mit „!!!“ gekennzeichnet.
- Über den Menüpunkt „File“ -> „New“ -> „Source“ -> „Template“ kann die entsprechende Script-Vorlage aufgerufen werden.
- Wenn die busspezifischen Parameter identisch sind, muss das Script nicht angepasst werden. Dies gilt allerdings nur dann, wenn bei der Initialisierung des Buses (:InitFieldbus;) nicht noch weitere busspezifische, optionale Parameter eingefügt worden sind. Wenn dies der Fall ist, müssen diese optionale Parameter mit der entsprechenden Script-Vorlage (Example) aus dem Protocol Developer verglichen werden.
- Über den Menüpunkt „File“ -> „New“ -> „Source“ -> „Example“ -> „Include“ kann die entsprechende Script-Vorlage aufgerufen werden.
Weblinks
- Protocol Developer (Zip-Datei)