Please follow the procedure described below how to carry out a '''"Reset Device"''':
 
Please follow the procedure described below how to carry out a '''"Reset Device"''':
 
#Install WINGATE and start.
 
#Install WINGATE and start.
#Beim erstmaligen Starten öffnet sich ein "Dialogfenster" mit dem Hinweis, dass der aktuell eingestellte COM-Port nicht existiert. Diese Dialogfenster mit '''"OK"''' bestätigen.
+
#At the first start will open a '''"dialog window"''' showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with '''"OK"'''.
#Danach muss das UNIGATE im '''Konfig.-Mode''' gestartet werden. In WINGATE erhält man die Einschaltmeldung des UNIGATEs.
+
#Then start the UNIGATE in '''Konfig.-Mode'''. WINGATE will show the startup message of the UNIGATE.
#Über den Menüpunkt '''"Options"'''-->'''"Reset Device"''' kann dieser nun durchgeführt werden.
+
#Via the menue item '''"Options"'''-->'''"Reset Device"''' the reset can be carried out now.
#Das darauffolgenden Dialogfenster sollte nur mit '''"Ja"''' bestätigt werden, wenn der '''"Reset Device"''' wirklich durchgeführt werden soll. ''Hinweis'': Das Gerät wird in den Auslieferungszustand zurückgesetzt. Das geladene Script wird gelöscht. Ab der Version '''V2.64''' bleibt das '''Universalscript Deutschmann''' erhalten, sofern dies vor dem '''"Reset Device"''' im Gerät enthalten war.
+
#The then opening dialog window should be confirmed witht '''"Ja"''' only if the '''"Reset Device"''' really should be carried out. ''Note'': The device will be set back into delivery status. The loaded script will be deleted. From version '''V2.64''' the '''Universalscript Deutschmann''' will remain on the device, if this was loaded to it before '''"Reset Device"'''.
#Fertig
+
#Done.
  
 
== Weblinks ==
 
== Weblinks ==
 
*[http://www.deutschmann.de/produkte/download.php?file_id=577 Software WINGATE] (Zip-Datei)
 
*[http://www.deutschmann.de/produkte/download.php?file_id=577 Software WINGATE] (Zip-Datei)
 
*[http://www.deutschmann.de/produkte/download.php?file_id=678 Handbuch für WINGATE] (PDF-Datei)
 
*[http://www.deutschmann.de/produkte/download.php?file_id=678 Handbuch für WINGATE] (PDF-Datei)

Version vom 22. Januar 2015, 11:26 Uhr

Konfigurationssoftware WINGATE

With our configuration software WINGATE an UNIGATE can be configured and a compiled script (*.dcs)can be loaded.

Device configuration via application-RS232-interface

Please follow the procedure decribed below for configuration of the device via application-RS232-interface:

  1. Install WINGATE and start.
  2. At the first start will open a "dialog window" showing the note that the acutal selected COM-Port does not exist. Please confirm this Dialog window with "OK".
  3. Via the menue item "Options"-->"Port" the corresponding COM-Port which is connected to the application-RS232-interface of the UNIGATE has to be selected. This will be shown in the status bar.Attention: If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
  4. Then start the UNIGATE in Konfig.-Mode. WINGATE will show a startup message of the UNIGATE.
  5. Via the menue item "File"-->"Upload" the configuration of the UNIGATE can be read.
  6. Via the menue items "more items visible" und "more items editable" the parameters are highlighted which maybe changed.
  7. Via the menue item "File"-->"Download" the changed configuration now can be loaded into the UNIGATE.
  8. Via the menue item "File"-->"Save as" the configuration of the UNIGATE can be saved and filed.
  9. Done.

Device configuration via Debug-interface

Please follow the procedure described below for configuration of the device via debug-interface:

  1. Install WINGATE and start.
  2. At the first start will open a "dialog window" showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with "OK".
  3. Via the menue item "Options"-->"Port" the corresponding COM-Port which is connected to the debug-interface of the UNIGATE has to be selected. This will be shown in the status bar.Attention: If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
  4. Then start the UNIGATE in Debug-Mode. In the status bar will show the message "Device started in WINGATE-Mode".
  5. Via the menue item "Extras"-->"Upload_Config_Debug" the configuration of the UNIGATE can be read.
  6. Via the menue items "more items visible" und "more items editable" the parameters are highlighted which maybe changed.
  7. Via the menue item '"Extras"-->"Download_Config_Debug" the changed configuration now can be loaded into the UNIGATE.
  8. Via the menue item "File"-->"Save as" the configuration of the UNIGATE can be saved and filed.
  9. Done.

Script loading via application-RS232-interface

Please follow the procedure described below for loading a compiled script (*.dcs) via application-RS232-interface:

  1. Install WINGATE and start.
  2. At the first start will open a "dialog window" showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with "OK".
  3. Via the menue item "Options"-->"Port" the corresponding COM-Port which is connected to the application-RS232-interface of the UNIGATE has to be selected. This will be shown in the status bar.Attention: If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
  4. Then start the UNIGATE in Konfig.-Mode. WINGATE will show the startup message of the UNIGATE.
  5. Via the menue item "File"-->"Write Script" the needed script (*.dcs) can be selected and is loaded thereafter directly into the UNIGATE.
  6. After that the UNIGATE will start automatically new and displays a new startup message.
  7. Done.

Reset Device

Please follow the procedure described below how to carry out a "Reset Device":

  1. Install WINGATE and start.
  2. At the first start will open a "dialog window" showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with "OK".
  3. Then start the UNIGATE in Konfig.-Mode. WINGATE will show the startup message of the UNIGATE.
  4. Via the menue item "Options"-->"Reset Device" the reset can be carried out now.
  5. The then opening dialog window should be confirmed witht "Ja" only if the "Reset Device" really should be carried out. Note: The device will be set back into delivery status. The loaded script will be deleted. From version V2.64 the Universalscript Deutschmann will remain on the device, if this was loaded to it before "Reset Device".
  6. Done.