en:WINGATE: Unterschied zwischen den Versionen
Zur Navigation springen
Zur Suche springen
Reith (Diskussion | Beiträge) |
Reith (Diskussion | Beiträge) |
||
Zeile 23: | Zeile 23: | ||
#Via the menue item '''"Extras"'''→'''"Upload_Config_Debug"''' the configuration of the UNIGATE® can be read. A '''"dialogue window'''" will show up with the note: '''"Restart UNIGATE in Run-Mode and confirm"'''. Before to be able to confirm this '''"dialogue window"''' with '''"OK"''', UNIGATE® has to be started again. Only when in the status bar the message will appear '''"Device starting in WINGATE-Mode"''' , this '''"Dialogue Window"''' maybe confirmed with '''"OK"'''. Now the upload will be processed. During this process the message '''"Upload"''' will be shown in the status bar. After a successfull upload will appear the message '''"Upload finished"''' in the Status bar. | #Via the menue item '''"Extras"'''→'''"Upload_Config_Debug"''' the configuration of the UNIGATE® can be read. A '''"dialogue window'''" will show up with the note: '''"Restart UNIGATE in Run-Mode and confirm"'''. Before to be able to confirm this '''"dialogue window"''' with '''"OK"''', UNIGATE® has to be started again. Only when in the status bar the message will appear '''"Device starting in WINGATE-Mode"''' , this '''"Dialogue Window"''' maybe confirmed with '''"OK"'''. Now the upload will be processed. During this process the message '''"Upload"''' will be shown in the status bar. After a successfull upload will appear the message '''"Upload finished"''' in the Status bar. | ||
#Via the menue items '''"more items visible"''' und '''"more items editable"''' more parameters (if available) are shown and maybe changed. | #Via the menue items '''"more items visible"''' und '''"more items editable"''' more parameters (if available) are shown and maybe changed. | ||
− | #Via the menue item ''''"Extras"'''→'''"Download_Config_Debug"''' the changed configuration now can be loaded into the UNIGATE®. | + | #Via the menue item ''''"Extras"'''→'''"Download_Config_Debug"''' the changed configuration now can be loaded into the UNIGATE®. A '''"dialogue window'''" will show up with the note: '''"Restart UNIGATE in Run-Mode and confirm"'''. Before to be able to confirm this '''"dialogue window"''' with '''"OK"''', UNIGATE® has to be started again. Only when in the status bar the message will appear '''"Device starting in WINGATE-Mode"''' , this '''"Dialogue Window"''' maybe confirmed with '''"OK"'''. Now the download will be processed. During this process the message '''"Downloading..."''' will be shown in the status bar. After a successfull upload will appear the message '''"Download finished"''' in the status bar. |
− | |||
− | |||
#Via the menue item '''"File"'''→'''"Save as"''' the configuration of the UNIGATE® can be saved and filed. | #Via the menue item '''"File"'''→'''"Save as"''' the configuration of the UNIGATE® can be saved and filed. | ||
#Done. | #Done. |
Version vom 3. Mai 2016, 11:39 Uhr
The software WINGATE is a configuration software for Deutschmann UNIGATE®-devices.
Inhaltsverzeichnis
Device Configuration
The device configuration maybe done via Application Interface (RS232) or via Debug-Interface.
Application Interface (RS232)
- Install WINGATE and start.
- At the first start will open a "dialog window" showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with "OK".
- Via the menue item "Options"→"Port" select the used COM-Port. If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
- After that the UNIGATE® has to be connected via Application Interface (RS232) and to be started in Configuration Mode (Rotary switches S4 + S5 set to "FF"). WINGATE will show the startup message of the UNIGATE®.
- Via the menue item "File"→"Upload" the configuration of UNIGATE® can be read now.
- Via the menue items "more items visible" und "more items editable" more parameters (if available) are shown and maybe changed.
- Via the menue item "File"→"Download" the changed configuration now can be loaded into the UNIGATE®.
- Via the menue item "File"→"Save as" the configuration of UNIGATE® can be saved and filed.
- Done.
Debug Interface
- Install WINGATE and start.
- At the first start will open a "dialog window" showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with "OK".
- Via the menue item "Options"→"Port" select the used COM-Port. If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
- After that the UNIGATE® has to be connected via Debug Interface and to be started in Data Exchange Mode (Rotary switches S4 + S5 set to "00").In the status bar will appear the message "Device started in WINGATE-Mode".
- Via the menue item "Extras"→"Upload_Config_Debug" the configuration of the UNIGATE® can be read. A "dialogue window" will show up with the note: "Restart UNIGATE in Run-Mode and confirm". Before to be able to confirm this "dialogue window" with "OK", UNIGATE® has to be started again. Only when in the status bar the message will appear "Device starting in WINGATE-Mode" , this "Dialogue Window" maybe confirmed with "OK". Now the upload will be processed. During this process the message "Upload" will be shown in the status bar. After a successfull upload will appear the message "Upload finished" in the Status bar.
- Via the menue items "more items visible" und "more items editable" more parameters (if available) are shown and maybe changed.
- Via the menue item '"Extras"→"Download_Config_Debug" the changed configuration now can be loaded into the UNIGATE®. A "dialogue window" will show up with the note: "Restart UNIGATE in Run-Mode and confirm". Before to be able to confirm this "dialogue window" with "OK", UNIGATE® has to be started again. Only when in the status bar the message will appear "Device starting in WINGATE-Mode" , this "Dialogue Window" maybe confirmed with "OK". Now the download will be processed. During this process the message "Downloading..." will be shown in the status bar. After a successfull upload will appear the message "Download finished" in the status bar.
- Via the menue item "File"→"Save as" the configuration of the UNIGATE® can be saved and filed.
- Done.
Script loading via Application Interface (RS 232)
- Install WINGATE and start.
- At the first start will open a "dialog window" showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with "OK".
- Via the menue item "Options"→"Port" select the used COM-Port. If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
- Then start the UNIGATE® in Configuration-Mode. WINGATE will show the startup message of the UNIGATE®.
- Via the menue item "File"→"Write Script" the needed script (*.dcs) can be selected and is loaded thereafter directly into the UNIGATE®.
- After that the UNIGATE® will start automatically new and displays a new startup message.
- Done.
Reset Device
- Install WINGATE and start.
- At the first start will open a "dialog window" showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with "OK".
- Via the menue item "Options"→"Port" select the used COM-Port. If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
- Then start the UNIGATE® in Configuration-Mode. WINGATE will show the startup message of the UNIGATE®.
- Via the menue item "Options"→"Reset Device" the reset can be carried out now.
- The then opening dialog window should be confirmed with "Ja" only if the "Reset Device" really should be carried out. The loaded script will be deleted. Note for UNIGATE® CL: From version V2.64 the Universalscript Deutschmann will remain on the device, if this was loaded to it before "Reset Device"is executed.
- Done.
Weblinks
- Software WINGATE (Zip-Datei)
- Handbuch für WINGATE (PDF-Datei)