en:WINGATE: Unterschied zwischen den Versionen

Aus Deutschmann Wiki
Zur Navigation springen Zur Suche springen
Zeile 43: Zeile 43:
 
#At the first start will open a '''"dialog window"''' showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with '''"OK"'''.
 
#At the first start will open a '''"dialog window"''' showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with '''"OK"'''.
 
#Via the menue item '''"Options"'''→'''"Port"''' select the used COM-Port. If there exists no real COM-Port at the PC, an [[USB-to-RS232 converter]] is needed.
 
#Via the menue item '''"Options"'''→'''"Port"''' select the used COM-Port. If there exists no real COM-Port at the PC, an [[USB-to-RS232 converter]] is needed.
 +
#After that the UNIGATE® has to be connected via [[UNIGATE® interfaces|'''Application Interface (RS232)''']] and to be started in '''Configuration Mode''' (Rotary switches '''S4 + S5''' set to '''"FF"'''). WINGATE will show the startup message of the UNIGATE®.
 
#Then start the UNIGATE® in '''Configuration-Mode'''. WINGATE will show the startup message of the UNIGATE®.
 
#Then start the UNIGATE® in '''Configuration-Mode'''. WINGATE will show the startup message of the UNIGATE®.
 
#Via the menue item '''"Options"'''→'''"Reset Device"''' the reset can be carried out now.
 
#Via the menue item '''"Options"'''→'''"Reset Device"''' the reset can be carried out now.

Version vom 3. Mai 2016, 11:02 Uhr

Konfigurationssoftware WINGATE

The software WINGATE is a configuration software for Deutschmann UNIGATE®-devices.

Device Configuration

The device configuration maybe done via Application Interface (RS232) or via Debug-Interface.

Application Interface (RS232)

  1. Install WINGATE and start.
  2. At the first start will open a "dialog window" showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with "OK".
  3. Via the menue item "Options""Port" select the used COM-Port. If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
  4. After that the UNIGATE® has to be connected via Application Interface (RS232) and to be started in Configuration Mode (Rotary switches S4 + S5 set to "FF"). WINGATE will show the startup message of the UNIGATE®.
  5. Via the menue item "File""Upload" the configuration of UNIGATE® can be read now.
  6. Via the menue items "more items visible" und "more items editable" more parameters (if available) are shown and maybe changed.
  7. Via the menue item "File""Download" the changed configuration now can be loaded into the UNIGATE®.
  8. Via the menue item "File""Save as" the configuration of UNIGATE® can be saved and filed.
  9. Done.

Debug Interface

  1. Install WINGATE and start.
  2. At the first start will open a "dialog window" showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with "OK".
  3. Via the menue item "Options""Port" select the used COM-Port. If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
  4. After that the UNIGATE® has to be connected via Debug Interface and to be started in Data Exchange Mode (Rotary switches S4 + S5 set to "00").In the status bar will appear the message "Device started in WINGATE-Mode".
  5. Via the menue item "Extras""Upload_Config_Debug" the configuration of the UNIGATE® can be read. A "dialog window" will show up with the note: "Restart UNIGATE in Run-Mode and confirm". Before to be able to confirm this "dialog window" with "OK", UNIGATE® has to be started again. Only when in the status bar the message will appear "Device starting in WINGATE-Mode" , this "Dialog Window" maybe confirmed with "OK". Now the upload will be processed. During this process the message "Upload" will be shown in the status bar. After a successfull upload will appear the message "Upload finished" in the Status bar.
  6. Via the menue items "more items visible" und "more items editable" more parameters (if available) are shown and maybe changed.
  7. Via the menue item '"Extras""Download_Config_Debug" the changed configuration now can be loaded into the UNIGATE®. A "dialog window" will show up with the note: "Restart UNIGATE in Run-Mode and confirm". Before to be able to confirm this "dialog window" with "OK", UNIGATE® has to be started again. Only when in the status bar the message will appear "Device starting in WINGATE-Mode" , this "Dialog Window" maybe confirmed with "OK". Now the download will be processed. During this process the message "Downloading..." will be shown in the status bar. After a successfull upload will appear the message "Download finished" in the status bar.
  8. Via the menue item "File""Save as" the configuration of the UNIGATE® can be saved and filed.
  9. Done.

Script loading

  1. Install WINGATE and start.
  2. At the first start will open a "dialog window" showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with "OK".
  3. Via the menue item "Options""Port" select the used COM-Port. If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
  4. After that the UNIGATE® has to be connected via Application Interface (RS232) and to be started in Configuration Mode. WINGATE will show the startup message of the UNIGATE®.
  5. Then start the UNIGATE® in Configuration-Mode. WINGATE will show the startup message of the UNIGATE®.
  6. Via the menue item "File""Write Script" the needed script (*.dcs) can be selected and is loaded thereafter directly into the UNIGATE®.
  7. After that the UNIGATE® will start automatically new and displays a new startup message.
  8. Done.

Reset Device

  1. Install WINGATE and start.
  2. At the first start will open a "dialog window" showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with "OK".
  3. Via the menue item "Options""Port" select the used COM-Port. If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
  4. After that the UNIGATE® has to be connected via Application Interface (RS232) and to be started in Configuration Mode (Rotary switches S4 + S5 set to "FF"). WINGATE will show the startup message of the UNIGATE®.
  5. Then start the UNIGATE® in Configuration-Mode. WINGATE will show the startup message of the UNIGATE®.
  6. Via the menue item "Options""Reset Device" the reset can be carried out now.
  7. The then opening dialog window should be confirmed with "Ja" only if the "Reset Device" really should be carried out. The loaded script will be deleted. Note for UNIGATE® CL: From version V2.64 the Universalscript Deutschmann will remain on the device, if this was loaded to it before "Reset Device"is executed.
  8. Done.

Weblinks