WINGATE

Aus Deutschmann Wiki
Zur Navigation springen Zur Suche springen
Konfigurationssoftware WINGATE

With our configuration software WINGATE an UNIGATE can be configured and a compiled script (*.dcs)can be loaded.

Device configuration via application-RS232-interface

Please follow the procedure decribed below for configuration of the device via application-RS232-interface:

  1. Install WINGATE and start.
  2. At the first start will open a "dialog window" showing the note that the acutal selected COM-Port does not exist. Please confirm this Dialog window with "OK".
  3. Via the menue item "Options"-->"Port" the corresponding COM-Port which is connected to the application-RS232-interface of the UNIGATE has to be selected. This will be shown in the status bar.Attention: If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
  4. Then start the UNIGATE in Konfig.-Mode. WINGATE will show a startup message of the UNIGATE.
  5. Via the menue item "File"-->"Upload" the configuration of the UNIGATE can be read.
  6. Via the menue items "more items visible" und "more items editable" the parameters are highlighted which maybe changed.
  7. Via the menue item "File"-->"Download" the changed configuration now can be loaded into the UNIGATE.
  8. Via the menue item "File"-->"Save as" the configuration of the UNIGATE can be saved and filed.
  9. Done.

Device configuration via Debug-interface

Please follow the procedure described below for configuration of the device via debug-interface:

  1. Install WINGATE and start.
  2. At the first start will open a "dialog window" showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with "OK".
  3. Via the menue item "Options"-->"Port" the corresponding COM-Port which is connected to the debug-interface of the UNIGATE has to be selected. This will be shown in the status bar.Attention: If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
  4. Then start the UNIGATE in Debug-Mode. In the status bar will show the message "Device started in WINGATE-Mode".
  5. Via the menue item "Extras"-->"Upload_Config_Debug" the configuration of the UNIGATE can be read.
  6. Via the menue items "more items visible" und "more items editable" the parameters are displayed which maybe changed.
  7. Via the menue item '"Extras"-->"Download_Config_Debug" the changed configuration now can be loaded into the UNIGATE.
  8. Via the menue item "File"-->"Save as" the configuration of the UNIGATE can be saved and filed.
  9. Done.

Script laden über die Applikations-RS232-Schnittstelle

Nachfolgend wird beschrieben wie ein kompiliertes Script (*.dcs) über die Applikations-RS232-Schnittstelle geladen wird:

  1. WINGATE installieren und anschließend starten.
  2. Beim erstmaligen Starten öffnet sich ein "Dialogfenster" mit dem Hinweis, dass der aktuell eingestellte COM-Port nicht existiert. Dieses Dialogfenster mit "OK" bestätigen.
  3. Über den Menüpunkt "Options"->"Port" muss der entsprechende COM-Port angewählt werden, der mit der Applikations-RS232-Schnittstelle des UNIGATEs verbunden ist. Im Anschluss wird diese in der Statusleiste angezeigt. Achtung: Wenn kein echter COM-Port mehr am PC vorhanden ist, wird ein USB-RS232-Konverter benötigt.
  4. Danach muss das UNIGATE im Konfig.-Mode gestartet werden. In WINGATE erhält man die Einschaltmeldung des UNIGATEs.
  5. Über den Menüpunkt "File"-->"Write Script" wird nun das benötigte Script (*.dcs) ausgewählt und im Anschluss direkt in das UNIGATE geladen.
  6. Danach startet das UNIGATE automatisch neu und erzeugt eine neue Einschaltmeldung.
  7. Fertig.

Weblinks