With our configuration software WINGATE an UNIGATE can be configured and a compiled script (*.dcs)can be loaded.
Inhaltsverzeichnis
Device configuration via application-RS232-interface
Please follow the procedure decribed below for configuration of the device via application-RS232-interface:
- Install WINGATE and start.
- At the first start will open a "dialog window" showing the note that the acutal selected COM-Port does not exist. Please confirm this Dialog window with "OK".
- Via the menue item "Options"-->"Port" the corresponding COM-Port which is connected to the application-RS232-interface of the UNIGATE has to be selected. This will be shown in the status bar.Attention: If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
- Then start the UNIGATE in Konfig.-Mode. WINGATE will show a startup message of the UNIGATE.
- Via the menue item "File"-->"Upload" the configuration of the UNIGATE can be read.
- Via the menue items "more items visible" und "more items editable" the parameters are highlighted which maybe changed.
- Via the menue item "File"-->"Download" the changed configuration now can be loaded into the UNIGATE.
- Via the menue item "File"-->"Save as" the configuration of the UNIGATE can be saved and filed.
- Done.
Device configuration via Debug-interface
Please follow the procedure described below for configuration of the device via debug-interface:
- Install WINGATE and start.
- At the first start will open a "dialog window" showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with "OK".
- Via the menue item "Options"-->"Port" the corresponding COM-Port which is connected to the debug-interface of the UNIGATE has to be selected. This will be shown in the status bar.Attention: If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
- Then start the UNIGATE in Debug-Mode. In the status bar will show the message "Device started in WINGATE-Mode".
- Via the menue item "Extras"-->"Upload_Config_Debug" the configuration of the UNIGATE can be read.
- Via the menue items "more items visible" und "more items editable" the parameters are highlighted which maybe changed.
- Via the menue item '"Extras"-->"Download_Config_Debug" the changed configuration now can be loaded into the UNIGATE.
- Via the menue item "File"-->"Save as" the configuration of the UNIGATE can be saved and filed.
- Done.
Script loading via application-RS232-interface
Please follow the procedure described below for loading a compiled script (*.dcs) via application-RS232-interface:
- Install WINGATE and start.
- At the first start will open a "dialog window" showing the note that the acutal selected COM-Port does not exist. Please confirm this dialog window with "OK".
- Via the menue item "Options"-->"Port" the corresponding COM-Port which is connected to the application-RS232-interface of the UNIGATE has to be selected. This will be shown in the status bar.Attention: If there exists no real COM-Port at the PC, an USB-to-RS232 converter is needed.
- Then start the UNIGATE in Konfig.-Mode. WINGATE will show the startup message of the UNIGATE.
- Via the menue item "File"-->"Write Script" the needed script (*.dcs) can be selected and is loaded thereafter directly into the UNIGATE.
- After that the UNIGATE will start automatically new and displays a new startup message.
- Done.
Weblinks
- Software WINGATE (Zip-Datei)
- Handbuch für WINGATE (PDF-Datei)