Programming cables for electronic cam controls
If you want to configure or programm a cam control by using the software WINLOC 32-Basic-or-Comfort-Version, you need a corresponding programming cable. Please find here a list of the now available programming cables with the corresponding cam controls.
- General Note: For the configuration and programming of the cam control by WINLOC 32-Basic-or-comfort Version, the PC needs a real COM-Port. If there isn't a real COM-Port at the PC,then a USB-to-RS232 converter has to be used.
Art.-No. | Device | Description | cable description | length | Art.-No. |
---|---|---|---|---|---|
V3231 | ROTARNOCK 4 | TN65-4096-4-IPB-E-N | Programming cable for ROTARNOCK - 232/PB | 2m | V3467 |
V3427 | ROTARNOCK 80 | TN65-0360-80-I232-E-N | Programming cable for ROTARNOCK - 232/PB | 2m | V3467 |
V3428 | ROTARNOCK 80-PB (PROFIBUS) | TN65-0360-80-IPB-E-N | Programming cable for ROTARNOCK - 232/PB | 2m | V3467 |
V3429 | ROTARNOCK 80 | TN65-0360-80-I232-E-IFN | Programming cable for ROTARNOCK IFN - 232 | 2m | V3712 |
V3430 | ROTARNOCK 80-PB (PROFIBUS) | TN65-0360-80-IPB-E-IPN | Programming cable for ROTARNOCK - PB/PN IP65 | 2m | V3655 |
V3413 | ROTARNOCK 100 | TN65-4096-100-I485-E-N | Programming cable for ROTARNOCK (Dicnet) | 2m | V3480 |
V3431 | ROTARNOCK 100 | TN65-4096-100-I232-E-N | Programming cable for ROTARNOCK - 232/PB | 2m | V3467 |
V3432 | ROTARNOCK 100 | TN65-4096-100-I485-E-IFN | Programming cable for ROTARNOCK (Dicnet) IP65 | 2m | V3483 |
V3433 | ROTARNOCK 100 | TN65-4096-100-I232-E-IFN | Programming cable for ROTARNOCK IFN - 232 | 2m | V3712 |
V3628 | ROTARNOCK 100 | TN65-4096-100-I232-E-N-X089 | Programming cable for ROTARNOCK - X89 via TERM 6 | 2m | V2293-02 |
V3628 | ROTARNOCK 100 | TN65-4096-100-I232-E-N-X089 | Programming cable for ROTARNOCK - X89 via WINLOC 32 | 3m | V2142-03 |
V3406 | ROTARNOCK 100-PB (PROFIBUS) | TN65-4096-100-IPB-E-N | Programming cable for ROTARNOCK - 232/PB | 2m | V3467 |
V3434 | ROTARNOCK 100-PB (PROFIBUS) | TN65-4096-100-IPB-E-IPN | Programming cable for ROTARNOCK - PB/PN IP65 | 2m | V3655 |
V3795 | ROTARNOCK 100-PN (PROFINET) | TN65-4096-100-IPN-E-IPN | Programming cable for ROTARNOCK - PB/PN IP65 | 2m | V3655 |
V3542 | LOCON 90 | LOCON 90 | Programming cable for LOCON 90/100/200 | 2m | V3964 |
V3374 | LOCON 100 | LOCON 100 | Programming cable for LOCON 90/100/200 | 2m | V3964 |
V3485 | LOCON 200 | LOCON 200 | Programming cable for LOCON 90/100/200 | 2m | V3964 |
V3397 | LOCON 100-PB (PROFIBUS) | LOCON 100-PB | Programming cable for LOCON 90/100/200 | 2m | V3964 |
V3487 | LOCON 200-PB (PROFIBUS) | LOCON 200-PB | Programming cable for LOCON 90/100/200 | 2m | V3964 |
V3589 | LOCON 100-MB (Modbus) | LOCON 100-MB | Programming cable for LOCON 90/100/200 | 2m | V3964 |
V4310 | LOCON 200-MB (Modbus) | LOCON 200-MB | Programming cable for LOCON 90/100/200 | 2m | V3964 |
Programming cabels for ROTARNOCK 1, 2 and 3
Whether the programming cable of a ROTARNOCK 100 can be used when a device is exchanged for a 'ROTARNOCK 1, 2 or 3' must be checked using the item designation. The following points must be observed:
- 232 = ROTARNOCK has an RS232 interface only
- 485 = ROTARNOCK has an RS485-(DICNET) interface only
- PB = ROTARNOCK has a PROFIBUS interface and an RS232 interface
- PN = ROTARNOCK has a PROFINET interface and an RS232 interface
- IF = ROTARNOCK with protection class IP65 with 28 pin round connector
- IP = ROTARNOCK with protection class IP65 with interated bus system and 16 pin round connector
Example:TN65-1000-1-L485-E-N
This is a ROTARNOCK 1 with an RS485-(DICNET) interface with protection class IP54 and 25 pin D-Sub connector. The right programming cable is V3480.