Device replacement LOCON 1 & 2: Unterschied zwischen den Versionen
Zur Navigation springen
Zur Suche springen
Biegel (Diskussion | Beiträge) |
Reith (Diskussion | Beiträge) |
||
Zeile 5: | Zeile 5: | ||
#The serial-no. or the article-no.(Vxxxx) of the old device has to be known in order to offer a corresponding new device. | #The serial-no. or the article-no.(Vxxxx) of the old device has to be known in order to offer a corresponding new device. | ||
#If a [[TERM 6 (English)|TERM 6]] or a [[TERM 24 (English)|TERM 24]] is already under use, we have to know the serial-no. of this device in order to check the compatibilty with the new device. | #If a [[TERM 6 (English)|TERM 6]] or a [[TERM 24 (English)|TERM 24]] is already under use, we have to know the serial-no. of this device in order to check the compatibilty with the new device. | ||
− | #For the configuration and programming of the new device with [[WINLOC 32 (English)|WINLOC 32]]-Basic-or Comfortversion would be needed a corresponding programming cable. '''Note:''' It has to be checked in every single case if this programming cable may be used also for a needed reading of the old device. | + | #For the configuration and programming of the new device with [[WINLOC 32 (English)|WINLOC 32]]-Basic-or Comfortversion would be needed a corresponding programming cable. '''Note:''' It has to be checked in every single case if this programming cable may be used also for a needed reading out of the old device. |
#For programming of the new device with WINLOC 32-Basic-or-comfort Version, the PC is in need of a real COM-Port. If there exists no more real COM-Port at the PC, then a [[USB-to-RS232 converter]] has to be used. | #For programming of the new device with WINLOC 32-Basic-or-comfort Version, the PC is in need of a real COM-Port. If there exists no more real COM-Port at the PC, then a [[USB-to-RS232 converter]] has to be used. | ||
#For front panel installation: The cam controls LOCON 16 ad LOCON 17 have smaller dimensions, maybe an adapter plate has to be mounted. | #For front panel installation: The cam controls LOCON 16 ad LOCON 17 have smaller dimensions, maybe an adapter plate has to be mounted. | ||
'''For a corresponding offer please let us know the serial-no. or the article-no. (Vxxxx) of the old device and, in case, the serial-no. of an already used TERM 6 resp. TERM 24.''' | '''For a corresponding offer please let us know the serial-no. or the article-no. (Vxxxx) of the old device and, in case, the serial-no. of an already used TERM 6 resp. TERM 24.''' |
Aktuelle Version vom 16. Juli 2014, 16:04 Uhr
Depending on the version, LOCON 1 and LOCON 2 can be replaced by a corresponding LOCON 16 or LOCON 17. In order to ensure a proper and fast replacement, we would need the following information and components:
- The serial-no. or the article-no.(Vxxxx) of the old device has to be known in order to offer a corresponding new device.
- If a TERM 6 or a TERM 24 is already under use, we have to know the serial-no. of this device in order to check the compatibilty with the new device.
- For the configuration and programming of the new device with WINLOC 32-Basic-or Comfortversion would be needed a corresponding programming cable. Note: It has to be checked in every single case if this programming cable may be used also for a needed reading out of the old device.
- For programming of the new device with WINLOC 32-Basic-or-comfort Version, the PC is in need of a real COM-Port. If there exists no more real COM-Port at the PC, then a USB-to-RS232 converter has to be used.
- For front panel installation: The cam controls LOCON 16 ad LOCON 17 have smaller dimensions, maybe an adapter plate has to be mounted.
For a corresponding offer please let us know the serial-no. or the article-no. (Vxxxx) of the old device and, in case, the serial-no. of an already used TERM 6 resp. TERM 24.